AXIS 241Q/S Blade - Rack Solution Installation Guide
About This Document use the equipment according to the instruction manual This document is intended as an addendum to the video server User’s Manual. It includes instructions for installing the Axis Rack Mounted Video Server Solution on your network. Later versions of this document will be posted to the Axis Web site, as required. Australia - This electronic device meets the requirements of the Radio communications (Electromagnetic Compatibility) Standard 1998 AS/NZS 3548.
AXIS 241Q/S Blade - Rack Solution Installation Guide The Axis Video Server Rack will fit up to 12 rack mounted Axis Video Servers (Blade Servers). This installation guide describes the hardware installation of the Axis Rack Mounted Video Server Solution.
AXIS 241Q/S Blade - Rack Solution Installation Guide AXIS 241Q/S Blade Video Server Read the following information to familiarize yourself with the AXIS 241Q/S Blade video server making particular note of where the connectors and indicators are located: Control Button See the AXIS 241Q/S User’s Manual for information on the use of the control button.
AXIS 241Q/S Blade - Rack Solution Installation Guide Bus Connector - Physical interface to the I/O Block Connector on the rack DIP Switch(es) - A corresponding line termination switch for each of the supported video outputs (1-4 video outputs depending on the model). • All units are shipped with the line termination enabled for each supported video input; that is, with the DIP switches set to ON (Down position).
AXIS 241Q/S Blade - Rack Solution Installation Guide The I/O Terminal Block Axis Blade Video Servers connect to an I/O terminal block used for transmitting data over multi-drop communication lines: • RS-485 Pan/Tilt devices • RS-232 Pan/Tilt devices • External triggering (typically associated with CCTV equipment) The Axis Blade Video Servers support several Pan/Tilt device drivers that are available from the Axis Web site at www.axis.
AXIS 241Q/S Blade - Rack Solution Installation Guide Connecting the video server to the rack Please read through the instructions below before beginning the installation. 1. Connect the power cable to the power connector on the rack. Make sure that the green power indicator is lit. Power Indicator 2. Note the Serial number (S/N) on the front panel on the video server. You need to know this to set the IP address. 3.
AXIS 241Q/S Blade - Rack Solution Installation Guide Technical Specifications The following specifications are applicable for the complete Axis Rack Mounted Video Server Solution i.e. an AXIS Video Server Rack with a mounted AXIS 241Q/S Blade Video Server.