Product Instructions 25734 C O M M U N I C A T I O N S Before attempting to connect or operate this product, please read these instructions completely.
IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to. 4. Follow Instructions - All operating and user instructions should be followed. 5. Electrical Connections - Only a qualified electrician should make electrical connections. 6.
ELECTRICAL SPECIFICATIONS (OUTDOOR ONLY): ! Power 24VAC, Class 2 Only 2. Open the housing assembly box. Note there is a small roll of Teflon Tape that will be needed during installation, put it aside. (Picture 2) Teflon Tape 52 watts at 24 VAC (accessories) Heater: 50 watts Blower: 2 watts Picture 2 NOTE: This unit is designed for operation in an upright position. Installing the unit upside down may cause damage to the internal equipment, and will void the warranty.
Installing the Axis 213 Camera 1. Install the camera onto the quick release bracket using (2) 10-32 x 3/8” screws and star washers provided in the packet. Attach cameras using these (2) holes ½" 2. In the kit there are (8) aluminum spacers - (4) 1" and (4) ½". Thread (2) spacers - (1) 1" and (1) ½" - on top of each of the (4) 2" spacers that are already located on the base bracket inside the housing. ½" + 1" spacers 1" 2" 3.
Installing Axis 213 Camera (cont.) CAMERA POWER Connect the power plug and the ethernet cable to the back of the camera. 4. Mount the camera assembly in the housing, sliding the (3) open screw slots over the (3) screws in the housing. Slide the bracket forward then tighten the captive screw on the bracket.
Installing Axis 214 Camera Attach cameras using these (3) holes 1" 3. Place (3) 8 x 32 x s Phillips head screws on the top of the spacer as shown above. Be sure to place the screws so that they line up with the open slots on the mounting plate. 4. Slide the mounting plate with camera into position on top of spacers. Secure 3 screws and captive fastener. 1. Install the AXIS 214 camera to the 2685 mounting plate using the (3) 3mm x 12mm bolt and lock washers provided. 2.
Installing Axis 231D/232D Camera 4. When the locking buttons hit the end of the keyhole slots. Tighten the locking screw. Then put the camera assembly 1. Install the camera onto the quick release bracket. Loosen one of the screws on the bottom of the camera, see diagram below. aside. Locking screw Loosen screw 2. Place quick release bracket onto the bottom of the camera, making sure that the (3) locking buttons line up with the keyhole slots in the Q/R bracket.
Installing Axis 231D/232D Camera (cont.) 7. Then start (3) 8-32x3/8” phillips head screws onto the (3) ½" spacers inside the housing. Be sure to place the screws so that they line up with the (3) open slots on the quick release bracket, the screws on the bottom of the camera, see diagram below. (3) 8-32 x 3/8"screws 8. Locate the connector block, which is included with the camera. Then located the connector block bracket, which is included with the housing.
Installing Axis 231D/232D Camera (cont.) 11. To manage the input cable running from the connector block to the camera use the (2) cable tie mounts and cable ties that are located in the housing packet. Cable Tie Mounts 13. Attach the camera assembly to the housing by sliding the (3) open screw slots over the screws in the housing. Slide the bracket forward, and the tighten the captive screw on the bracket. Captive screw Cable Ties Open screw slots 12.
Installing Axis 233 Camera 1. Note the position of the mounting holes on the camera bracket (see diagram below). 4. Now remove the Base Bracket. Camera Bracket Mounting holes Mounting holes for housing 2. Since the 233 camera operates on 24vac, the power board that is located inside the housing is not needed. The remove the power board, start by loosening the screws on the terminal block and disconnect the orange and red wires. 3.
Installing Axis 233 Camera (cont.) 6. Mount the Axis 233 camera bracket and Q/R plate (Quick Release plate) as shown. Quick Release (Q/R) plate 7. Place the Quick Release plate onto the bottom of the camera, Make sure that the locking screws on the AXIS 233 camera line up with the keyhole slots on the Q/R plate. Keyhole Slots Slide the camera into the keyhole slots by targeting the locking screw(s). Keyhole Slots Keyhole Slots 8. Turn the camera counter-clockwise. 9.
INSTALLING THE HOUSING ASSEMBLY: ! REMOVING AND ATTACHING THE DOME ASSEMBLY: Be sure the bracket is properly and securely mounted to a supporting structure capable of rigidly holding the weight of the entire unit. 1. Attach the dome assembly to the housing top by lining up the three pins with the three keyhole slots. Insert the dome assembly into the housing and then rotate the dome assembly clockwise. Then tighten the (3) screws on the front of the dome assembly.
POWER WIRING Two plug-in wall transformers are included with the housing. Use one to provide power for the heater and blower in the housing, and the other for the camera. Determine where the transformers will be located, then run two sets of power wires into the wall mount bracket (Four total power wires). Use the chart below to determine the correct gauge of wire needed based on the length of the run and the 30vA power line.
Exploded View for Replacement Parts 16 9 8 7 4 6 5 3 2 1 Replacement Parts List Part Number Description 1 RPFD7015 Lower Trim Ring 2 FD7T Tinted Replacement Capsule FD7C Clear Replacement Capsule 3 RPFD703 Dome Clamping Bracket 4 RPFD072 24 Vac Heater 5 RPFD080 (12 Vdc) Blower (Used In 24v Housings) 6 RPFD060 Camera Bracket 7 RPRH707 Connection Pcb 8 RPFD040 Housing Hardware 9 RPFD709 Housing Top 16 RPFD711 Pendant Mount Bracket - 14 -