Service manual

28
When enabling or disabling single selections the
opposite state of the current setting will be used. For
example: if you currently have selection 210 enabled
and you go into change it, it will change to disabled.
When enabling or disabling a range, shelf or the
entire machine. The setting will change to the
opposite of the lowest selection number in the
range, shelf or machine being set. For example if
you are changing the top shelf, and selection 210 is
set to enable while 212 -216 are set to disable, then
you would be disabling the top shelf from Golden-
Eye because the lowest selection number on the
shelf was set to enable.
CHECK MOTOR SCAN
This function is used to verify the state of the
selection motors in the Satellite (MultiMate). To
access this Mode, press the Service Switch 5 times,
then press 3 on the selection keypad the display will
show the results of the last Motor Scan Test. Press
the
key to scroll through the results. To initiate
a new scan of the motors Press the 1 key. The
display will say Scanning Motors when
completed the display will say Scanning motors
done press
to continue. Press the key to
scroll through the results.
Set Credit Ret TO
This function is used to set the amount of time the
customer has to make another selection before their
change is returned. During this time period, the
customer can make a selection, add more money to
make another selection or press the coin return to
receive their change. To access this mode, press the
Service Switch 5 times, then press 4 on the selection
keypad the display will show “Set Credit Ret TO”.
Press the
key the display will show “Set Credit
Return” in the top line and “Timeout : XX:XX in the
bottom line, where XX:XX is the currently set
timeout. Use the numeric keypad to enter the
minutes and seconds. Press the
key to lock in
the change.
NOTE: The default time is 30 seconds.
Minimum time is 00:00
Maximum time is 05:00
Major Component Description
AC DISTRIBUTION BOX
BevMax 3 5800-4
110 VAC units
Main Power Switch / Plug Interrupts hot side
of incoming power
to all components in
machine.
15 Amp Outlet (110 VAC) Provides power to
Refrigeration unit.
Transformer (T1) Provides 24 Volt
power to the
Controller Board.
Service Door Switches
If 2 Switches - Left Switch (10 Amp) – in XY Motor
Circuits, Port Door Motor Circuit, and Picker Motor
Circuit (Power Interrupt Switch).
If 2 Switches - Right Switch
(.1 Amp) – in
Controller and Electronic Lock Circuit (Lock Switch).
If One Switch
- the red & black wires are in
Controller Circuit and the two gray wires are go to
XY Motor Circuits, Port Door Motor Circuit, and
Picker Motor Circuit. (Power Interrupt Switch).
General Maintenance
The most important facets of proper care and
maintenance of your machine are the electrical
power supplied to it, leveling, and cleanliness of the
machine.
POWER
The machine must be connected to a dedicated 120
VAC, 15 Amp circuit (U.S. and Canada).
CAUTION:
REMOVE POWER TO THE AC DISTRIBUTION
BOX BEFORE CLEANING OR WHEN ANY
ELECTRICAL COMPONENTS ARE CONNECTED /
DISCONNECTED FOR TESTING OR
REPLACEMENT.
Periodically inspect the power supply
cord for damage. If the cord or plug is
worn or damaged, it must be replaced
with a power supply cord of the same
type, size and specification as originally
provided with the machine. DO NOT
USE THE VENDING MACHINE UNTIL
THE WORN OR DAMAGED CORD IS
REPLACED.
The Ground Fault Circuit Interrupter (GFCI) must be
tested frequently and before each use in accordance
with the instructions provided on the GFCI device.
IF THE GFCI DOES NOT PASS THE TEST, DO
NOT USE THE MACHINE. Unplug the supply cord
from the receptacle and call the Dixie-Narco
Technical Support Group for assistance at 1-803-
266-5001.
CAUTION:
REMOVE POWER TO THE AC DISTRIBUTION
BOX BEFORE CLEANING OR WHEN ANY
ELECTRICAL COMPONENTS ARE CONNECTED /
DISCONNECTED FOR TESTING OR
REPLACEMENT.