User manual

AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
4.Selecttheoptionsthatmatchhowthelockcircuitswillbeconnected.
5.Ifalockmonitorwillbeused,selectLockmonitorandthenselecttheoptionsthatmatchhowthelockmonitorcircuits
willbeconnected.
6.Iftheinputconnectionsfromreaders,REXdevices,anddoormonitorsshallbesupervised,selectEnablesupervisedinputs.
Formoreinformation,seeUseSupervisedInputsonpage19.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
Youcanconnectonelockmonitorperdoorcontroller.Soifyouusedouble-lockdoors,onlyoneofthelockscanhavealock
monitor.Iftwodoorsareconnectedtothesamedoorcontroller,lockmonitorscannotbeused.
Motorizedlocksmustbeconguredassecondarylocks.
DoorMonitorOptions
Thefollowingdoormonitoroptionsareavailable:
DoormonitorSelectedbydefault.Eachdoorhasitsowndoormonitorthat,forexample,willsignalwhenthedoorhas
beenforcedopenoropentoolong.Deselectifnodoormonitorwillbeused.
-Opencircuit=CloseddoorSelectifthedoormonitorcircuitisnormallyopen.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisclosed.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisopen.
-Opencircuit=OpendoorSelectifthedoormonitorcircuitisnormallyclosed.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisopen.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisclosed.
CancelaccesstimeoncedoorisopenedSelecttopreventtailgating,thatis,stopunauthorizedvisitorsfromaccessing
thedoor.Thedoorwilllockimmediatelyafterthedoorhasbeenopened.Whenthedoorcloses,thedoorwillbelockedand
cannotbeopeneduntilauserrequestsandisgrantedaccessagain.
Thefollowingdoormonitortimeoptionsareavailable:
AccesstimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoorremains
unlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhethertheaccesstimehasexpiredor
not.Ifthedoorremainsunopened,itlockswhenthesetaccesstimehasbeenreached.
OpentoolongtimeSetthenumberofsecondsthedoorisallowedtostayopen.Ifthedoorisstillopenwhenthe
opentoolongtimehasbeenreached,thedooropentoolongalarmistriggered.Setupanactionruletocongurewhich
actiontheopentoolongeventshalltrigger.
Pre-alarmtimeApre-alarmisawarningsignalthatistriggeredbeforetheopentoolongtimehasbeenreached.It
tellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(theperson
enteringthedoor)thatthedoorneedstobeclosedortherealalarm,thedooropentoolongalarm,willgooff.Setthe
numberofsecondsbeforethedooropentoolongalarmistriggeredthesystemshallgivethepre-alarmwarningsignal.
Todisablethepre-alarm,setthepre-alarmtimeto0.
Forinformationabouthowtosetupanactionrule,seeSetUpActionRulesonpage36.
LockOptions
DeselectDoormonitortomakethefollowinglocktimeoptionsavailable:
DoorunlockedtimeSetthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoor
remainsunlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhetherthedoorunlockedtime
hasexpiredornot.Ifthedoorremainsunopened,itlockswhenthesetdoorunlocktimehasbeenreached.
Pre-locksignaltimeApre-locksignalisawarningsignalthatistriggeredbeforethedoorlocks.Ittellstheadministrator
and,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(thepersonenteringthedoor)that
thedoorwilllocksoon.Setthenumberofsecondsbeforethedoorlocksthesystemshallgivethepre-lockwarning
17