User manual

AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
ActivelowSelectifactivatingtheREXdeviceclosesthecircuit.
ActivehighSelectifactivatingtheREXdeviceopensthecircuit.
REXdoesnotunlockdoorSelectifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor.
Thedoorforcedopenalarmwillnotbetriggeredaslongastheuseropensthedoorwithintheaccesstime.Deselectif
thedoorshallunlockautomaticallywhentheuseractivatestheREXdevice.
Important
Ifthedoorcontrollerhasonlybeenconguredwithonedoorbeforeitisupgradedtormware1.15orlaterfromrmware
1.10,REXdoesnotunlockdoorwillbenon-selectableatrst.TomakeREXdoesnotunlockdoorselectable,gotoSetup
>HardwareCongurationandclickResetandstartanewhardwareconguration.Thensetuptherulesforthedoors
connectedtothedoorcontrollerandaddthemtogroups,seeManageDoors.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
UseSupervisedInputs
Supervisedinputsreportonthestatusoftheconnectionbetweenthedoorcontrollerandthereaders,REXdevices,anddoor
monitors.Iftheconnectionisinterrupted,aneventisactivated.
Tousesupervisedinputs:
1.Installendoflineresistorsonalltheusedinputs.Seetheconnectiondiagramonpage64.
2.GotoSetup>HardwareRecongurationandselectEnablesupervisedinputs.Youcanalsoenablesupervisedinputs
duringthehardwareconguration.
SupervisedInputCompatibility
Thefollowingconnectorssupportsupervisedinputs:
ReaderI/Oconnectortamperingsignal.Seepage60.
Doorconnector.Seepage6
1.
Readersandswitchesthatcanbeusedwithsupervisedinputsinclude:
HIDreaderswithinternal1kΩpull-upto5V.
Readersandswitcheswithinternal1kΩpull-upto5V.
Readersandswitcheswithoutinternalpull-up.
VerifytheHardwareConnections
Whenthehardwareinstallationandcongurationiscomplete,andanytimeduringthedoorcontroller’slifetime,youcanverifythe
functionoftheconnecteddoormonitors,locksandreaders.
Toverifythecongurationandaccessthevericationcontrols,gotoSetup>HardwareConnectionVerication.
VericationControls
DoorstateVerifythecurrentstateofthedoormonitor,dooralarmsandlocks.ClickGetcurrentstate.
LockManuallytriggerthelock.Bothprimarylocksandsecondarylocksifthereareanywillbeaffected.ClickLockor
Unlock.
LockManuallytriggerthelocktograntaccess.Onlyprimarylockswillbeaffected.ClickAccess.