User manual
AXISA1001NetworkDoorController&AXISEntryManager
SystemConfiguration
CreateaNewHardwareConguration
Tocreateanewhardwarecongurationfromthebeginning:
1.GotoSetup>HardwareCongurationandclickStartnewhardwareconguration.
Iftheproduct’shardwarehasnotbeenconguredbeforeorhasbeendeleted,HardwareCongurationwillbeavailablein
thenoticationpanelintheOverviewpage.
2.Selectadooroptiondependingonthenumberofdoors,one(1)ortwo(2),thatwillbeconnectedtotheAxisproduct.
3.EnteradescriptivenameforeachdoorandclickNext.Itisrecommendedtoprovidethedoorswithuniquedescriptive
namessothattheyeasilycanbeidentifedbyanyonewhowilladministratethesystem.
YoucanalsoeditthenameoftheAxisproduct.Thedefaultnameincludestheserialnumberforeasyidentication.
4.Selectthedoormonitorandlockoptionsthatmatchtherequirementsandthetypeoflockconnectionsthatwillbeused
andclickNext.Formoreinformation,seeCongureLocksandDoorMonitorsonpage14andLockOptionsonpage15.
5.SelectthetypesofreadersthatwillbeusedandclickFinish.Formoreinformation,seeCongureReadersandREXDevices
onpage16andReaderandREXDeviceOptionsonpage16.
6.Inthedialogthatappearsaftercompletingtheconguration,clickOKorclickthelinktoviewthehardwarepinchart.
Toprintthehardwarepinchart,clickPrintHardwarePinChartontheHardwarePinChartpage.
Tocancelthehardwareconguration,clickCancel.Thiscanbedoneinanyofthehardwarecongurationpages.
CongureLocksandDoorMonitors
1.Ifadoormonitorwillbeused,selectDoormonitorandthenselecttheoptionthatmatcheshowthedoormonitor
circuitswillbeconnected.
2.Ifthedoorlockshalllockimmediatelyafterthedoorhasbeenopened,selectCancelaccesstimeoncedoorisopened.
3.Specifythedoormonitortimeoptionsor,ifnodoormonitorwillbeused,thelocktimeoptions.
4.Selecttheoptionsthatmatchhowthelockcircuitswillbeconnected.
5.Ifalockmonitorwillbeused,selectLockmonitorandthenselecttheoptionsthatmatchhowthelockmonitorcircuits
willbeconnected.
6.Iftheinputconnectionsfromreaders,REXdevices,anddoormonitorsshallbesupervised,selectEnablesupervisedinputs.
Formoreinformation,seeUseSupervisedInputsonpage16.
Note
•Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
•Youcanconnectonelockmonitorperdoorcontroller.Soifyouusedouble-lockdoors,onlyoneofthelockscanhavealock
monitor.Iftwodoorsareconnectedtothesamedoorcontroller,lockmonitorscannotbeused.
•Motorizedlocksmustbeconguredassecondarylocks.
DoorMonitorOptions
Thefollowingdoormonitoroptionsareavailable:
•Doormonitor–Selectedbydefault.Eachdoorhasitsowndoormonitorthat,forexample,willsignalwhenthedoorhas
beenforcedopenoropentoolong.Deselectifnodoormonitorwillbeused.
-Opencircuit=Closeddoor–Selectifthedoormonitorcircuitisnormallyopen.Thedoormonitorgivesthedoor
opensignalwhenthecircuitisclosed.Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisopen.
14