User guide

Output-On-
Stall
Multi-Axis
Stop
CHAPTER
4.
APPLICATION DESIGN
59
You
can
select
the
Output-on-Stall
function with
the
Turn
on
Output
# 1
on
Stall Detect (FSE) command. This
is
useful for
signaling
other
components
in
your
system
that
a
stall
has
occurred.
If you
enter
the
FSE
1
command.
the
AX
programmable
Output
# 1 goes
on
(current flows)
when
a
stall
is
detected
and
remains
on
untn
a new move begins. ThIs
command
is
valid only
jf
the
Stall Detection
has
been
enabled
(FSB
1),
and
jf
the
AX
is
set
to Encoder Step Mode (FSB1).
Command
MN
FSB1
OW10
FSH1
FS01
FSE1
A2
V.1
012800
G
Description
Sets the system in the preset mode
Enables encoder mode
Selects backlash to be 10 motor steps
Enables stall detect function
Stops motor
if
a stall is detected
Turns on Output 1 if stall is detected
Sets acceleration to 2 revs/sec
2
Sets velocity to
0.1
rps
Sets distance to 12,800 encoder steps
Execute the move (Go)
While
the
motor
is moving. you
can
cause
a
stall
by
holding
the
shaft. If you
can
not
manually
stall
the
motor, you
can
Simulate a
stall
by carefully disconnecting
the
+5V encoder
lead from
pin
# 1
on
the
AX
encoder connector.
When
the
stall
occurs,
Output
1 Is
turned
on
and
the
motor
stops
(this signals
you
that
the
motor
has
stalled). The
motor
will come to a stop.
On
a multi-axis
AX
system, you
may
wish
to
have
all
axes
stop
motion
jf
a stall is detected
on
any
axis.
You
can
select
this
function
via
the
Kill
Motion
on
Trigger 3 (FSF)
command.
When
selected with the
FSFI
command,
a signal
on
the
Trigger 3
input
terminates
the
move immediately,
thus
functioning
as
a remote
stop
input.
Follow
the
following
steps
to
set
up
your
AX
system
to
terminate
the
multi-axis moves
when
a
stall
is
detected
on
any
axis:
1.
Set
the
first
AX
unit
to
Turn
on
Output
1
on
Stall (FSE1)
2. Connect
Output
1 (pin
15)
on
the
first
AX
unit
to Trigger 3
(pin
11)
on
all
the
other
AX
units
in
the
daisy-chain.