Manual

10
ENGLISH
EN
8.3. Water Connection
The unit should be connected to your water
supply by way of a water faucet. The water
pressure should fall between 14.5 and 72.5 PSI. If
the water pressure is excessive, a pressure
regulator must be installed.
To carry out connection, connect the mains pipe
to the appliance connection pipe, interposing a
shut-off valve (A) to interrupt the water supply
when necessary.
The pipe used to discharge the water must be
heat resistant and allow for the free flow of the
discharge water. A funnel may be used between
the unit discharge pipe and the floor drain but you
should never restrict or reduce the diameter of the
discharge pipe.
The following operations are to be carried out only
by specialized technical personnel.
! Having verified that available water system
is adequate you can go ahead and make
connection:
1. Clear the pipe of any ferrous waste by letting
a certain amount of water flow through.
2. Place the cooker in the desired position and
close to the water-main.
3. Position the appliance level, adjusting the feet
of the cooker.
4. Connect mains pipe to machine pipe using a
mechanical filter and an interception valve.
5. Connect machine outlet pipe (fig. 1) to a
suitable manifold that withstands high
temperatures.
8.4. Gas Connection
Before connecting up the gas consult the
gas board, all the installation and maintenance
operations should be carried out by the gas board
or by authorized fitters.
Make sure the data of the rating plate correspond
to the mains values. The rating plate is located at
the bottom of the screen-door panel.
Having verified that the gas supply system
available is adequate you can go ahead with the
connection:
To carry out connection, connect the mains pipe
to the appliance connection pipe, interposing a
shut-off valve to interrupt the water supply when
necessary.
1. Connect the mains pipe to the machine pipe
(see fig.) using a quick closing interception
valve which is easy to reach. You must use a
pressure regulator to set the manifold
pressure as in tab. 4.1
2. Go ahead with setting up and adjusting as
described in paragraph 2.4.1.
3. Make all the checks listed below.
After connection, check that there are no gas
leaks.
! Never use flames to search for gas leaks.