Instruction manual

HyTechWorks©2013 – V3.1 43
Control Inputs). If the input is low level effective, put a green tick in Active Low
column. Then click Applyand OKto save the settings.
The operate the main menu Config”->”Motor Home/SoftLimits. The A-axis
settings are used for tool setting operation. If the tool setter is located on the
negative direction on Z-axis (moving negatively to seek tool setter), put a green
tick in column Home Neg. Speed %defines the % of G0 speed on Z-axis slow
movement. When this setting generates stepping pulses more than 1000Hz, the
accuracy is also affected. In this case, the homing accuracy in theory is
distance per step · pulse frequency
1000