3 Rubbing line Not to be noticeable. Minor
4 Allowable density Above defects should be separated more than 10mm each other. Minor
5 Rainbow Not to be noticeable. Minor
6 Dot size
To be 95% 105% of the dot size (Typ.) in drawing.
Partial defects of each dot (ex. pin-hole) should be treated as Spot.
(see Screen Cosmetic Criteria (Operating) No.1)
Minor
7 Uneven brightness
(only back-lit type
module)
Uneven brightness must be BMAX / BMIN 2
- BMAX : Max. value by measure in 5 points
- BMIN : Min. value by measure in 5 points
Divide active area into 4 vertically and horizontally.
Measure 5 points shown in the following figure.
Minor
Note :
(1) Size : d = (long length + short length) / 2
(2) The limit samples for each item have priority.
(3) Complex defects are defined item by item, but if the numbers of defects are defined in above table, the total
number should not exceed 10.
(4) In case of concentration, even the spots or the lines of disregarded size should not allowed. Following
three situations should be treated as concentration.
- 7 or over defects in circle of 5mm.
- 10 or over defects in circle of 10mm.
- 20 or over defects in circle of 20mm.
: Measuring points