User manual

AXIS M1143–L
Technical Specications
Digital Input
3
Connect to GND to activate, or leave oating (unconnected)
to deactivate.
0to+40VDC
Digital Output
4
Internal connection to ground when activated, oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltag e transients .
Max load =100 mA
Max voltage = + 40 V DC
3.3 V max 50 mA
1
2
3
4
Performance Considerations
When settings up your system, it is important to consider how various setting s and situations will affect perfor m ance. Some factors
affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some aff ect both. If the load on the
CPU reaches its maxim um, this wi ll also affect the fra m e rate.
The following factors are among the most imp ortant to consider:
High image resolution and/or lower compression levels result in images containing more data. Bandwidth affected.
Access by large numbers of Motion JPEG and/or unicast H.264 clients. Bandwidth affected.
Simultaneous viewing of different streams (resolution, compression) by different clients. Effect on frame rate and bandwidth.
Accessing Motion JPEG and H.264 video stre ams s imultane ous ly. Frame rate and bandwidth affe cted.
Heavy usage of event settings a ffect the product’s CPU load. Frame rate affected.
Heavy network utilization due to poor infrastructure . Bandwidth affected.
Viewing on poorly performing client computers lowers perceived performance. Frame rate affected.
52