User`s manual
FEATURES AND FONTS
AXIS AX-3 Cobra+ Technical Reference 43
SECTION 5
FEATURES AND FONTS
By configuring the protocol converter, a number of features can be accessed. This
Section describes the most commonly used features. Note that some features only
apply to either 5219 emulation or 4214 emulation.
Redefinition of the Lead-In and Trailer Sequences
The redefinition is done using either Configuration from the System or using
Configuration from a Terminal ( the User’s Manual). The Transparency Lead-In
Sequence (parameter #041) and Trailer Sequence (parameter #043) are redefined by
programming the appropriate parameters following the syntax described page 36.
Notes: 1. The characters in this parameter are EBCDIC characters and therefore the ‘/’
character is used for programming (see page 37).
2. Function #205 saves all parameters permanently.
3. The new Trailer Sequence must be used to exit parameter programming.
4. Extended Emulation Mode has to be active. See page 33.
Result:
Example: %P
=41,/!?</
Note 1
=43,/>&/
Note 1
=205
Note 2
>&
Note 3
Param. Title Contents
#040 Escape Character $6C (%)
#041 Transparency Lead-In Sequence $4F $6F $4C (!?<)
#042 Configuration Lead-In Sequence $6C $D7 (%P)
#043 Transp./Config. Trailer Sequence $6E $50 (>&)