User`s manual

SOLVING PROBLEMS
AXIS AX-3 Cobra+ Technical Reference 75
To produce a hexdump, do as follows:
Switch the protocol converter and printer off and on.
Set the rotary switch to ‘9’.
Wait for approx 3 seconds until the SYSTEM indicator starts to flash.
Set the rotary switch to ‘4’ for system hexdump or ‘3’ for ASCII hexdump.
Send the print job you want to analyze.
The data will now be printed in hexadecimal form.
Set the rotary switch to ‘9’.
The SYSTEM indicator stops flashing.
Select device address and restart the protocol converter.
The Emma System If your dealer/distributor has an Axis Emma system, you can record data sent between
the host and the protocol converter and send it for analysis. Contact your
dealer/distributor for more information.