User`s manual

THE PARAMETER LIST (3812/5219)
AXIS AX-3 Cobra+ Technical Reference 81
#035 XON/XOFF
Does not apply to the Axis 330 Cobra.
Handshake protocol for serial communication.
Note: 1. If a serial cable is used from the protocol converter to the printer and XON/XOFF
is set to Yes, #039 PC-Host Time-out must be set to 0.
#036 XON Character
Does not apply to the Axis 330 Cobra.
XON character for serial communication.
#037 XOFF Character
Does not apply to the Axis 330 Cobra.
#038 Inverted Busy
Does not apply to the Axis 330 Cobra.
Serial interface DTR (Ready/Busy) signal polarity.
#039 PC-Host Time-out
Does not apply to the Axis 330 Cobra.
Timer value controlling the automatic switching between PC and host input.
Note: 1. When an input gains control, the other inputs will be held busy until the PC-Host
Time-out has expired.
Value Description
Yes XON/XOFF protocol
*No Ready/Busy protocol
Value Description
$00 - $FF XON character
$11 Factory default
Value Description
$00 - $FF XOFF character
$13 Factory default
Value Description
Yes DTR is low when printer is busy
*No DTR is high when the printer is busy
Value Description
0 - 255 Valid range
0 Host input only
*10 10 seconds delay
254 254 seconds delay (maximum)
255 PC serial input only