User`s manual
THE PARAMETER LIST (3812/5219)
AXIS AX-3 Cobra+ Technical Reference 83
#042 Configuration Lead-In Sequence
The sequence bypasses the normal emulation and starts a Configuration from the
System session.
Notes: 1. The Configuration Lead-In Sequence will be automatically set when the Extended
Emulation Control Sequence is received.
2. The sequence must be entered in EBCDIC character codes or literals
(e.g.<$6C,$D7> or </%P/> sets the Configuration Lead-In Sequence to ā%Pā).
3. Maximum 8 characters may be used as Configuration Lead-In Sequence.
Related
parameters:
#043 Transparency/Configuration Trailer Sequence
#044 Extended Emulation Control Sequence
#043 Transparency/Configuration Trailer Sequence
The sequence ends a Multi-Byte Transparency or Configuration from the System
session and resumes normal emulation mode.
Notes: 1. The Transparency/Configuration Trailer Sequence will be automatically set when
the Extended Emulation Control Sequence is received.
2. This sequence must be entered in EBCDIC character codes or literals (e.g. <$6C>
or </%/> sets the Transparency/Configuration Trailer Sequence to ā%ā).
3. Maximum 8 characters may be used as Transparency/Configuration Trailer
Sequence.
4. Changing the trailer sequence will take immediate effect, i.e. the current
configuration session must be terminated with the new trailer sequence.
5. The Trailer Sequence must not be made empty since Multi-Byte Transparency or
Configuration from the System cannot be correctly terminated in that case.
Related
parameters:
#041 Transparency Lead-In Seq. #044 Extended Emulation Control Seq.
#042 Configuration Lead-In Seq.
Value Description
<CLI> Configuration start sequence
<empty> Factory default (Configuration from the System disabled)
Value Description
<TCT> Transparency/Configuration stop sequence
<empty> Factory default