User`s manual

THE PARAMETER LIST (4214)
Axis AX-3 Cobra+ Technical Reference 98
#007 Lock LPI
If set to Yes, the lpi defined in parameter #003 cannot be overridden by the Set Line
Density command.
Related
parameter:
#003 Line Density
#008 Lock Feeder Type
If set to Yes, the Feeder Type defined in parameter #004 cannot be overridden by the
Page Presentation Media command.
Related
parameter:
#004 Feeder Type
#009 Lock Print Quality
If set to Yes, the Print Quality defined in parameter #005 cannot be overridden by the
Page Presentation Media command.
Related
parameter:
#005 Print Quality
#010 System Language
See “Parameters (3812/5219 Emulation Only)” on page 79.
#011 Maximum Print Position
The setting in this parameter is used as the default value for maximum print position. It
is used at power up and when the Set Horizontal Format command selects the front
panel setting. The maximum print position is automatically adjusted by the protocol
converter not to be greater than allowed by the value defined in parameter #019.
Related
parameters:
#014 Lock Maximum Print Position
#019 Physical Maximum Print Position at 10 CPI
Value Description
*no Allow the Set Line Density command to set lpi
yes The Set Line Density command is disabled
Value Description
*no Allow the Page Presentation Media command to select Feeder Type
yes Feeder Type selection from the host is ignored
Value Description
*no Allow the Page Presentation Media command to select Print Quality
yes Print Quality selection from the host is ignored
Value Description
0 Maximum Print Position disabled
1 - 255 Valid Maximum Print Position setting
*132 Factory default