AXIS P3384–VE Fixed Dome User Manual
About this Document This manual is intended for administrators and users of the AXIS P3384–V/P3384–VE Fixed Dome Network Camera, and is applicable to firmware 5.60 and later. It includes instructions for using and managing the product on your network. Previous experience of networking will be of use when using this product. Some knowledge of UNIX or Linux-based systems may also be beneficial, for developing shell scripts and applications.
be connected using a shielded network cable (STP) that is properly grounded. Japan この装置は、クラスB 情報技術装置です。この装置は、家 庭環境で使用することを目 的としていますが、この装置が ラジオやテレビジョン受信機に近接して使用されると、 受 信障害を引き起こすことがあります。 取扱説明書に従って 正しい取り扱いをして下さい。 本製品は、シールドネット ワークケーブル(STP)を使用して接続してください。また 適切に接地してください。 Korea 이 기기는 가정용(B급) 전자파적합기기로서 주로 가정에 서 사용하는 것을 목적으로 하며, 모든 지역에서 사용할 수 있습니다. 적절히 접지된 STP (shielded twisted pair) 케이 블을 사용하여 제품을 연결 하십시오.
AXIS P3384–VE Fixed Dome Table of Contents Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors and Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Access the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Access from a Browser . . . . . . . . . .
AXIS P3384–VE Fixed Dome Table of Contents Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset to Factory Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Upgrade the Firmware . . . . . . .
AXIS P3384–VE Fixed Dome Hardware Overview Hardware Overview 1 1 2 3 4 5 6 7 2 3 4 5 6 7 Mounting bracket Unit casing Camera unit Fan output connector Heater. Caution! The heater may be hot.
AXIS P3384–VE Fixed Dome Hardware Overview Connectors and Buttons For technical specifications, see page 64. Network Connector RJ45 Ethernet connector with Power over Ethernet (PoE). NOTICE TICE NO Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network cable (STP) may be appropriate or required.
AXIS P3384–VE Fixed Dome Hardware Overview LED Indicators LED Color Indication Network Green Steady for connection to a 100 Mbit/s network. Flashes for network activity. Amber Steady for connection to a 10 Mbit/s network. Flashes for network activity. Unlit No network connection. Green Steady green for normal operation. Amber Steady during startup and when restoring settings. Red Slow flash for failed upgrade. Green Normal operation. Amber Flashes green/amber during firmware upgrade.
AXIS P3384–VE Fixed Dome Access the Product Access the Product To install the Axis product, refer to the Installation Guide supplied with the product. The product can be used with most operating systems and browsers. The recommended browsers are Internet Explorer with Windows, Safari with Macintosh and Firefox with other operating systems. See Technical Specifications on page 64. To view streaming video in Internet Explorer, allow installation of AXIS Media Control (AMC) when prompted.
AXIS P3384–VE Fixed Dome Access the Product To prevent network eavesdropping, the root password can be set via an encrypted HTTPS connection, which requires an HTTPS certificate. HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt traffic between web browsers and servers. The HTTPS certificate ensures encrypted exchange of information. See HTTPS on page 46. The default administrator user name root is permanent and cannot be deleted.
AXIS P3384–VE Fixed Dome Access the Product Click the Active/Inactive buttons to manually activate and inactive the product’s output port. For information about how to enable and configure output buttons, see page 28. The Manual Trigger button is used to trigger an action rule from the Live View page. For information about how to configure and enable the button, see Manual Trigger on page 11 . Click Snapshot to save a snapshot of the video image.
AXIS P3384–VE Fixed Dome Access the Product The Snapshot button takes a snapshot of the video image. The location where the image is saved can be specified in the AMC Control Panel. Click the View Full Screen button and the video image will fill the entire screen. Press ESC (Escape) on the computer keyboard to cancel full screen view. The Record button is used to record the current video stream. The location where the recording is saved can be specified in the AMC Control Panel.
AXIS P3384–VE Fixed Dome Access the Product Pan and Tilt bars – Use the arrows to pan and tilt the camera view, or click on a position on the bar to steer the camera view to that position. Focus bar – Click on a position on the focus bar to set the focus position. This will disable the product’s autofocus. To re-enable, use the PTZ control panel which is opened by clicking the Ctrl panel button (see above). The PTZ controls can be disabled under PTZ > Advanced > Controls, see Controls on page 29.
AXIS P3384–VE Fixed Dome Media Streams Media Streams The Axis product provides several audio and video stream formats. Your requirements and the properties of your network will determine the type you use. The Live View page in the product provides access to H.264 and Motion JPEG video streams, audio streams and to the list of available stream profiles. Other applications and clients can access video and audio streams directly, without going via the Live View page. How to Stream H.264 H.
AXIS P3384–VE Fixed Dome Media Streams The AMC Control Panel can be used to configure various video and audio settings. Please see the AXIS Media Control User’s Manual for more information. The AMC Control Panel is automatically installed on first use, after which it can be configured. Open the AMC Control Panel from: • Windows Control Panel (from the Start screen or Start menu) • Alternatively, right-click the video image in Internet Explorer and click Settings.
AXIS P3384–VE Fixed Dome Media Streams Note • = IP addess • The Axis product supports QuickTime 6.5.1 and later. • QuickTime may add latency to the video stream. • It may be possible to use other players to view the H.264 stream using the paths above, although Axis does not guarantee this.
AXIS P3384–VE Fixed Dome Set Up the Product Set Up the Product The Axis product can be configured by users with administrator or operator rights. To open the product’s Setup pages, click Setup in the top right-hand corner of the Live View page. • Administrators have unrestricted access to all settings. • Operators have access to all settings except System Options See also the online help . Basic Setup Basic Setup provides shortcuts to the settings that should be made before using the Axis product: 1.
AXIS P3384–VE Fixed Dome Video and Audio Video and Audio The video and audio settings can be used to optimize video and audio quality. You can configure the following: • Video stream settings. See page 18. • Stream profiles. See page 19. • Camera settings. See page 20. • View areas. See page 22. • Overlay image. See page 22. • Privacy mask. See page 23. • Focus and zoom. See page 24. • Audio settings. See page 24. • Audio clips. See page 26.
AXIS P3384–VE Fixed Dome Video and Audio The H.264 stream settings can be configured from the Video & Audio > Video Stream page. Select the H.264 tab. The settings defined in this page will apply to all H.264 streams that do not use a stream profile. The GOV length is the number of frames between two consecutive I-frames. Increasing the GOV length may save considerably on bandwidth requirements in some cases, but may also have an adverse affect on image quality. The Axis product supports the following H.
AXIS P3384–VE Fixed Dome Video and Audio • When setting up continuous recording. See Continuous Recording on page 44. • In the Live View page – select the stream profile from the Stream profile drop-down list. For quick setup, use one of the predefined stream profiles. Each predefined profile has a descriptive name, indicating its purpose. If required, the predefined stream profiles can be modified and new customized stream profiles can be created.
AXIS P3384–VE Fixed Dome Video and Audio Exposure Settings Configure the exposure settings to suit the image quality requirements in relation to lighting, frame rate and bandwidth considerations. Exposure control - This setting is used to adapt to the amount of light used. Automatic is the default setting and can be used in most situations. The shutter speed is automatically set to produce optimum image quality.
AXIS P3384–VE Fixed Dome Video and Audio The Day/Night shift level bar helps determine when the camera will shift from day mode to night mode. Normally, the camera automatically changes mode from day to night when very dark (level 100 in the slider). By setting Day/Night shift level to a lower value, the camera will change to night mode earlier. View Area A view area is a cropped part of the full view. Each view area is treated as a video source in Live View and has its own video stream and PTZ settings.
AXIS P3384–VE Fixed Dome Video and Audio 6. Click Save. To modify the date and time format, go to System Options > Date & Time. See Date & Time on page 48. Overlay Image An overlay image is a static image superimposed over the video stream. The image, for example a company logo, is used to provide extra information or to mask a part of the image. For more information about privacy masks, see Privacy Mask on page 23. To use an overlay image, the image must first be uploaded to the Axis product.
AXIS P3384–VE Fixed Dome Video and Audio For more information, see the online help Important Adding many privacy masks may affect the product’s performance. Focus & Zoom Focus and zoom should only be configured when installing or reinstalling the product. For installation instructions, refer to the product’s Installation Guide. See for more information. To set focus and zoom: 1. Install the camera as described in the Installation Guide. 2. Go to Video & Audio > Focus & Zoom. 3.
AXIS P3384–VE Fixed Dome Video and Audio Simplex — Network Camera microphone only - Audio captured by the product microphone is transmitted from the Axis product to one or more clients. To set the audio mode, go to Video & Audio > Audio Settings and select the desired mode from the Audio mode drop-down list. Audio Input An external microphone or a line source can be connected to the Audio-in connector. Configure the audio input settings under Video & Audio > Audio Settings.
AXIS P3384–VE Fixed Dome Video and Audio Audio Output An external speaker can be connected to the Audio-out connector (a built-in amplifier is required for this). The output can be connected to another amplifier with speakers. A stereo connector must be used for the audio out. Configure the audio output settings under Video & Audio > Audio Settings. Output gain - Control the volume (dB Full Scale) of the line audio output. If the sound is too low, choose a higher dB.
AXIS P3384–VE Fixed Dome Configure the Live View Page Configure the Live View Page You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page. • Stream Profile. See page 19. • Default Viewer for Browser. See page 27. • Viewer Settings. See page 27. • Action Buttons. These are the buttons described in Controls on the Live View Page on page 10. • User Defined Links. See page 28. • Output Buttons. See page 28.
AXIS P3384–VE Fixed Dome Configure the Live View Page • Select Use PTZ joystick mode as default to enable joystick mode. The mode can be changed temporarily from the PTZ control panel. • Select Enable recording button to enable recording from the Live View page. This button is available when using the AMC viewer. The recordings are saved to the location specified in the AMC Control Panel. See AXIS Media Control (AMC) on page 14.
AXIS P3384–VE Fixed Dome PTZ (Pan Tilt Zoom) PTZ (Pan Tilt Zoom) The PTZ menu is available if digital PTZ (pan, tilt and zoom) is enabled in the selected view area. For more information on view areas, see View Area on page 22. Preset Positions A preset position is a saved view that can be used to quickly steer the camera to a specific position. A preset position consists of the following values: • Pan and tilt positions • Focus position (manual or automatic) Each view area has its own preset positions.
AXIS P3384–VE Fixed Dome PTZ (Pan Tilt Zoom) To disable specific controls, deselect the options under Enable/Disable controls. If using multiple view areas, deselecting a control will only disable the control in the selected view area. Control Queue The administrator can set up a queue for PTZ controllers from PTZ > Control Queue. Once set up, the PTZ Control Queue buttons appear in the Live View page offering one viewer exclusive control for a limited period of time. Other users will be placed in queue.
AXIS P3384–VE Fixed Dome Detectors Detectors Camera Tampering Camera Tampering can generate an alarm whenever the camera is repositioned, or when the lens is covered, sprayed or severely defocused. To send an alarm, for example an email, an action rule must be set up. To configure tampering: 1. Go to Detectors > Camera Tampering. 2. Set the Minimum duration, that is, the time that must elapse before an alarm is generated. Increase time to prevent false alarms for known conditions that affect the image. 3.
AXIS P3384–VE Fixed Dome Detectors Note • Using the motion detection feature may decrease the product’s overall performance. • The position of the Motion Detection Window is relative to the orientation of the Camera. Changing the orientation of the camera will also change the position of the Motion Detection Window. Set Up Motion Detection Windows To set up a motion detection Include Window, follow these instructions: 1. Go to Detectors > Motion Detection. 2.
AXIS P3384–VE Fixed Dome Detectors Note • To trigger on small objects or movements, use several small motion detection windows rather than one large window and select a low object size. • To avoid triggering on small objects, select a high object size. • While monitoring an area where moving objects are not expected, select a high history level. This will cause motion detection to trigger as long as the object is present in the window. • To only detect flashing light, select a low sensitivity.
AXIS P3384–VE Fixed Dome Applications Applications Third party applications can be uploaded to and installed on the Axis product. Applications add functionality to the product, for example video analytics and intelligent video capabilities such as recognition, tracking, detection and counting. For information about available applications, downloads, trials and licenses, go to www.axis.
AXIS P3384–VE Fixed Dome Applications If the Axis product is reset to factory default, installed applications and their settings are removed. For information about factory default, see Reset to Factory Default Settings.
AXIS P3384–VE Fixed Dome Events Events The Event pages allow you to configure the Axis product to perform actions when different events occur. For example, the product can start a recording or send an email notification when motion is detected. The set of conditions that defines how and when the action is triggered is called an action rule. Set Up Action Rules An action rule defines the conditions that must be met for the product to perform an action, for example record video or send an email notification.
AXIS P3384–VE Fixed Dome Events The following example describes how to set up an action rule to record video to a network share if there is movement in the camera’s field of view. Set up motion detection and add a network share: 1. Go to Detectors > Motion Detection and configure a motion detection window. See page 32 2. Go to System Options > Storage and set up the network share. See page 55. Set up the action rule: 1. Go to Events > Action Rules and click Add. 2.
AXIS P3384–VE Fixed Dome Events • • • • • - Network – Trigger the rule if network connection is lost or restored. This can for example be used to start recording to the SD card. - Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This can for example be used to send maintenance notifications. Input Signal - Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O Ports on page 56.
AXIS P3384–VE Fixed Dome Events - Guard Tour – Start a guard tour. See Guard Tour on page 29. • Record Video – Record video and audio to a selected storage. To record audio, use AAC audio encoding and make sure that audio is enabled in the selected stream profile. • Send Images – Send images to a recipient. • Send Notifications – Send a notification message to a recipient. • Send SNMP Trap – Send an SNMP trap message to the operator.
AXIS P3384–VE Fixed Dome Events Network Share A network share can also be used as a storage device for recorded video. Go System Options > Storage to configure a network share before setting up a continuous recording or an action rule to record video. For more information about storage devices, see Storage on page 54.
AXIS P3384–VE Fixed Dome Events 2. Enter a descriptive name and recurrence pattern. 3. Click OK. To use the recurrence in an action rule, first select Time from the Trigger drop-down list in the Action Rule Setup page and then select the recurrence from the second drop-down list. To modify or remove recurrences, select the recurrence in the Recurrences List and click Modify or Remove.
AXIS P3384–VE Fixed Dome Recordings Recordings The Axis product can be configured to record video continuously or according to an action rule: • To start a continuous recording, see page 44. • To set up action rules, see page 36. • To access recordings, see Recording List on page 43. • To configure camera controlled storage, see Storage on page 54. Find Recordings Recordings stored on the SD card or network share can be accessed from the Recordings > List page.
AXIS P3384–VE Fixed Dome Recordings 2. To reduce the number of recordings displayed, select the desired options under Filter and click the Filter button to apply the filters. See also Find Recordings on page 42. 3. Select the recording and click Play. The recording will be played in a new browser window. Export Video Clip Recordings on the SD card or network share can be exported as video clips. It is possible to export a complete recording or a part of a recording.
AXIS P3384–VE Fixed Dome Recordings Continuous Recording The Axis product can be configured to continuously save video to a storage device. For information about storage devices, see Storage on page 54. To prevent the disk from becoming full, it is recommended to configure the disk to automatically remove old recordings. If a new stream profile is selected while a recording is ongoing, the recording will be stopped and saved in the recording list and a new recording with the new stream profile will start.
AXIS P3384–VE Fixed Dome Languages Languages Multiple languages can be installed in the Axis product. All web pages including the online help will be displayed in the selected language. To switch languages, go to Setup > Languages and first upload the new language file. Browse and locate the file and click the Upload Language button. Select the new language from the list and click Save.
AXIS P3384–VE Fixed Dome System Options System Options Security Users User access control is enabled by default and can be configured under System Options > Security > Users. An administrator can set up other users by giving them user names and passwords. It is also possible to allow anonymous viewer login, which means that anybody may access the Live View page.
AXIS P3384–VE Fixed Dome System Options 2. Select an HTTPS certificate from the list of installed certificates. 3. Optionally, click Ciphers and select the encryption algorithms to use for SSL. 4. Set the HTTPS Connection Policy for the different user groups. 5. Click Save to enable the settings. To access the Axis product via the desired protocol, enter https:// or http:// in the address field in a browser. The HTTPS port can be changed on the System Options > Network > TCP/IP > Advanced page. IEEE 802.
AXIS P3384–VE Fixed Dome System Options Certificates Certificates are used to authenticate devices on a network. Typical applications include encrypted web browsing (HTTPS), network protection via IEEE 802.1X and secure upload of images and notification messages for example via email. Two types of certificates can be used with the Axis product: Server/Client certificates - To authenticate the Axis product.
AXIS P3384–VE Fixed Dome System Options • Synchronize with computer time – Sets date and time according to the computer’s clock. With this option, date and time are set once and will not be updated automatically. • Synchronize with NTP Server – Obtains date and time from an NTP server. With this option, date and time settings are updated continuously. For information on NTP settings, see NTP Configuration on page 51. If using a host name for the NTP server, a DNS server must be configured.
AXIS P3384–VE Fixed Dome System Options 1. Acquire a free static IP address on the same network segment as the computer. 2. Locate the serial number (S/N) on the product label. 3. Open a command prompt and enter the following commands: Linux/Unix syntax arp -s temp ping -s 408 Linux/Unix example arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.
AXIS P3384–VE Fixed Dome System Options To register the Axis product with AXIS Internet Dynamic DNS Service, go to System Options > Network > TCP/IP > Basic. Under Services, click the AXIS Internet Dynamic DNS Service Settings button (requires access to the Internet). The domain name currently registered at AXIS Internet Dynamic DNS service for the product can at any time be removed. Note AXIS Internet Dynamic DNS Service requires IPv4.
AXIS P3384–VE Fixed Dome System Options HTTPS The HTTPS port used by the Axis product can be changed under System Options > Network > TCP/IP > Advanced. In addition to the default setting, which is 443, any port in the range 1024–65535 can be used. To enable HTTPS, go to System Options > Security > HTTPS. For more information, see HTTPS on page 46. NAT traversal (port mapping) for IPv4 A network router allows devices on a private network (LAN) to share a single connection to the Internet.
AXIS P3384–VE Fixed Dome System Options SOCKS SOCKS is a networking proxy protocol. The Axis product can be configured to use a SOCKS server to reach networks on the other side of a firewall or proxy server. This functionality is useful if the Axis product is located on a local network behind a firewall, and notifications, uploads, alarms, etc need to be sent to a destination outside the local network (for example the Internet). SOCKS is configured under System Options > Network > SOCKS.
AXIS P3384–VE Fixed Dome System Options Note The initial password can only be set once. If the password is lost, the Axis product must be reset to factory default, see Reset to Factory Default Settings on page 58. UPnPTM The Axis product includes support for UPnPTM. UPnPTM is enabled by default and the product is automatically detected by operating systems and clients that support this protocol. UPnPTM can be disabled under System Options > Network > UPnPTM. RTP/H.
AXIS P3384–VE Fixed Dome System Options Mount and Unmount SD Card NOTICE TICE NO To prevent corruption of recordings, the SD card should always be unmounted before it is ejected. The SD card is automatically mounted when the card is inserted into the Axis product or when the product is started. A manual mount is only required if the card has been unmounted and not ejected and re-inserted. To unmount the SD card: 1. Open the Axis product’s webpages and go to Setup > System Options > Storage. 2.
AXIS P3384–VE Fixed Dome System Options 6. Click Connect. To clear all recordings and data from the Axis product’s folder on the designated share, click Clear under Storage Tools. To avoid filling the share, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings older than and select the number of days or weeks. To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
AXIS P3384–VE Fixed Dome System Options For information about firmware upgrade, see Upgrade the Firmware on page 59. Support Support Overview The System Options > Support > Support Overview page provides information on troubleshooting and contact information, should you require technical assistance. See also Troubleshooting on page 59. System Overview To get an overview of the Axis product’s status and settings, go to System Options > Support > System Overview.
AXIS P3384–VE Fixed Dome System Options For more information, see www.axis.com/developer File Upload Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload. Uploaded files are accessed through http:///local// where is the selected user group (viewer, operator or administrator) for the uploaded file.
AXIS P3384–VE Fixed Dome Troubleshooting Troubleshooting Check the Firmware Firmware is software that determines the functionality of network devices. One of your first actions when troubleshooting a problem should be to check the current firmware version. The latest version may contain a correction that fixes your particular problem. The current firmware version in the Axis product is displayed in the page Setup > Basic Setup and in Setup > About.
AXIS P3384–VE Fixed Dome Troubleshooting Emergency Recovery Procedure If power or network connection is lost during the upgrade, the process fails and the product becomes unresponsive. Flashing red Status indicator indicates a failed upgrade. To recover the product, follow the steps below. The serial number is found on the product’s label. 1.
AXIS P3384–VE Fixed Dome Troubleshooting The IP address has been changed by DHCP IP addresses obtained from a DHCP server are dynamic and may change. If the IP address has been changed, use AXIS IP Utility or AXIS Camera Management to locate the product on the network. Identify the product using its model or serial number, or by the DNS name (if the name has been configured). If required, a static IP address can be assigned manually.
AXIS P3384–VE Fixed Dome Troubleshooting Lower frame rate than expected See Performance Considerations on page 68. Reduce the number of applications running on the client computer. Limit the number of simultaneous viewers. Check with the network administrator that there is enough bandwidth available. Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only key frames. Lower the image resolution.
AXIS P3384–VE Fixed Dome Troubleshooting Video cannot be recorded Check that the SD card is not write protected (that is, read only). SD card cannot be mounted Reformat the SD card and then click Mount. NOTICE TICE NO Formatting the card will remove all content, including all recordings, from the SD card.
AXIS P3384–VE Fixed Dome Technical Specifications Technical Specifications Function/group Video Audio Item Specifications Models AXIS P3384–VE Image sensor Progressive scan RGB CMOS 1/3” (effective) Lens Varifocal, remote focus and zoom, IR corrected, P-Iris control, megapixel resolution 3-9 mm, 84° - 30° view (horizontal angle of view, F1.
AXIS P3384–VE Fixed Dome Technical Specifications Function/group Item Specifications Network Security Password protection, IP address filtering, IEEE 802.1X* network access control, HTTPS* encryption, digest authentication, user access log, centralized certificate management. *This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/), and cryptographic software written by Eric Young (eay@cryptsoft.com).
AXIS P3384–VE Fixed Dome Technical Specifications Function/group Item Specifications General Casing Polycarbonate transparent cover Aluminum inner camera module with encapsulated electronics Casing Color: white NCS S 1002-B IP66- and NEMA 4X-rated, IK10 impact-resistant aluminum casing with integrated dehumidifying membrane Memory 256 MB RAM, 128 MB Flash Battery backed-up real-time clock Power Power over Ethernet (PoE) IEEE 802.3af Class 3; max 12.
AXIS P3384–VE Fixed Dome Technical Specifications Connectors I/O Connector 4-pin terminal block for: • • • • 4 3 2 1 Auxiliary power (DC output) Digital Input Digital Output 0 V DC (-) Function Pin 0 V DC (-) 1 Notes DC output 2 Can be used to power auxiliary equipment. Note: This pin can only be used as power out. 3.
AXIS P3384–VE Fixed Dome Technical Specifications 1 Tip 2 Ring 3 Sleeve Audio Input Microphone/Line in Ground Audio Output Line out (mono) Ground SD Card Slot Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10. Performance Considerations When setting up your system, it is important to consider how various settings and situations will affect performance.
User Manual AXIS P3384–VE Fixed Dome © Axis Communications AB, 2012 - 2014 Ver. M3.11 Date: September 2014 Part No.