AXIS P5414–E PTZ Dome Network Camera User Manual
About this Document This manual is intended for administrators and users of the AXIS P5414–E PTZ Dome Network Camera, and is applicable to firmware 5.55 and later. It includes instructions for using and managing the product on your network. Previous experience of networking will be of use when using this product. Some knowledge of UNIX or Linux-based systems may also be beneficial, for developing shell scripts and applications. Later versions of this document will be posted to the Axis website, as required.
Safety This product complies with IEC/EN/UL 60950-1 and IEC/EN/UL 60950-22, Safety of Information Technology Equipment. The product shall be grounded either through a shielded network cable (STP) or other appropriate method. The power supply used with this product shall fulfill the requirements for Safety Extra Low Voltage (SELV) and Limited Power Source (LPS) according to IEC/EN/UL 60950-1.
AXIS P5414–E PTZ Dome Network Camera Table of Contents Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors and Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Access the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Access from a Browser . . . .
AXIS P5414–E PTZ Dome Network Camera Table of Contents Check the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Upgrade the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symptoms, Possible Causes and Remedial Actions . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors . . . . . . . . . . . . . . . . . . . .
AXIS P5414–E PTZ Dome Network Camera Hardware Overview Hardware Overview 1 1 2 3 4 5 6 7 8 2 3 4 5 6 7 Control button Status LED indicator SD memory card slot Audio connector I/O connector Power connector Network connector (PoE+) Part number (P/N) & Serial number (S/N) Connectors and Buttons For technical specifications, see page 63. Network Connector RJ45 Ethernet connector with Power over Ethernet Plus (PoE+). NOTICE TICE NO The product shall be connected using a shielded network cable (STP).
AXIS P5414–E PTZ Dome Network Camera Hardware Overview I/O Connector Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to: • Digital output – For connecting external devices such as relays and LEDs.
AXIS P5414–E PTZ Dome Network Camera Hardware Overview LED Indicators LED Color Indication Status Unlit Connection and normal operation Amber Steady during startup. Flashes during firmware upgrade. Amber/red Flashes amber/red if network connection is unavailable or lost. Red Flashes red for firmware upgrade failure. Green Shows steady green for 10 seconds for normal operation after startup is completed.
AXIS P5414–E PTZ Dome Network Camera Access the Product Access the Product To install the Axis product, refer to the Installation Guide supplied with the product. The product can be used with most operating systems and browsers. The recommended browsers are Internet Explorer with Windows, Safari with Macintosh and Firefox with other operating systems. See Technical Specifications on page 63. To view streaming video in Internet Explorer, allow installation of AXIS Media Control (AMC) when prompted.
AXIS P5414–E PTZ Dome Network Camera Access the Product Access from the Internet Once connected, the Axis product is accessible on your local network (LAN). To access the product from the Internet you must configure your network router to allow incoming data traffic to the product. To do this, enable the NAT-traversal feature, which will attempt to automatically configure the router to allow access to the product. This is enabled from Setup > System Options > Network > TCP/IP Advanced.
AXIS P5414–E PTZ Dome Network Camera Access the Product The Live View Page The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control. Controls on the Live View Page Click View size to scale the image down to 800 pixels wide or to full scale.
AXIS P5414–E PTZ Dome Network Camera Access the Product To show the manual trigger buttons in the Live View page: 1. Go to Setup > Live View Config. 2. Under Action Buttons, select Show manual trigger button. AXIS Media Control viewer toolbar The AXIS Media Control viewer toolbar is available in Internet Explorer only. See AXIS Media Control (AMC) on page 14 for more information. The toolbar displays the following buttons: The Play button connects to the Axis product and starts playing a media stream.
AXIS P5414–E PTZ Dome Network Camera Access the Product Select Focus window to define an area of the camera's image that focus should be applied on. If the focus window is set from the Live View page, any change in the camera position will return the autofocus to the entire window. To set a permanent focus window, see Preset Positions on page 29 Click the Emulate joystick mode button and click in the image to move the camera view in the direction of the mouse pointer.
AXIS P5414–E PTZ Dome Network Camera Media Streams Media Streams The Axis product provides several audio and video stream formats. Your requirements and the properties of your network will determine the type you use. The Live View page in the product provides access to H.264 and Motion JPEG video streams, audio streams and to the list of available stream profiles. Other applications and clients can access video and audio streams directly, without going via the Live View page. How to Stream H.264 H.
AXIS P5414–E PTZ Dome Network Camera Media Streams The AMC Control Panel can be used to configure various video and audio settings. Please see the AXIS Media Control User’s Manual for more information. The AMC Control Panel is automatically installed on first use, after which it can be configured. Open the AMC Control Panel from: • Windows Control Panel (from the Start screen or Start menu) • Alternatively, right-click the video image in Internet Explorer and click Settings.
AXIS P5414–E PTZ Dome Network Camera Media Streams Note • = IP addess • The Axis product supports QuickTime 6.5.1 and later. • QuickTime may add latency to the video stream. • It may be possible to use other players to view the H.264 stream using the paths above, although Axis does not guarantee this.
AXIS P5414–E PTZ Dome Network Camera Set Up the Product Set Up the Product The Axis product can be configured by users with administrator or operator rights. To open the product’s Setup pages, click Setup in the top right-hand corner of the Live View page. • Administrators have unrestricted access to all settings. • Operators have access to all settings except System Options See also the online help .
AXIS P5414–E PTZ Dome Network Camera Video and Audio Video and Audio The video and audio settings can be used to optimize video and audio quality. You can configure the following: • Video stream settings. See page 18. • Stream profiles. See page 20. • Camera settings. See page 20. • Overlay image. See page 21. • Privacy mask. See page 23. • Audio settings. See page 24. • Audio clips. See page 25.
AXIS P5414–E PTZ Dome Network Camera Video and Audio • Compression. The compression level affects the image quality, bandwidth and file size of saved images; the lower the compression, the higher the image quality with higher bandwidth requirements and larger file sizes. • Rotate image. If required, the image can be rotated. • Maximum frame rate. To avoid bandwidth problems, the frame rate allowed to each viewer can be Limited to a fixed amount.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Stream Profiles A stream profile is a set of predefined stream settings including resolution, compression, frame rate and overlay settings. Stream profiles can be used: • When setting up recording using action rules. See Events on page 37. • When setting up continuous recording. See Continuous Recording on page 42. • In the Live View page – select the stream profile from the Stream profile drop-down list.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Enable Backlight compensation - Enable this option if a bright spot of light, for example a light bulb, causes other areas in the image to appear too dark. Exposure zones - This setting determines which part of the image is used to calculate the exposure. For most situations, the Auto setting can be used. For particular requirements, select a predefined area.
AXIS P5414–E PTZ Dome Network Camera Video and Audio It is also possible to display text when an action rule is triggered, see Use Overlay Text in an Action Rule. To enable overlays: 1. Go to Video & Audio > Video Stream and select the Image tab. 2. To include an overlay image, select Include overlay image at the coordinates. The overlay image must first be uploaded to the Axis product, see Overlay Image. 3. To include date and time, select Include date and Include time. 4.
AXIS P5414–E PTZ Dome Network Camera Video and Audio 2. Under Overlay Settings, select Include overlay image at the coordinates. 3. To control the image’s position, enter the X and Y coordinates. The X=0 and Y=0 position is the top left corner. If a part of the image is positioned outside the video image, the overlay image will be moved so that the whole image is visible. 4. Click Save. Use Overlay Text in an Action Rule Action rules, see page 37, can display an overlay text when the rule is triggered.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Audio Settings The audio functionality for each video stream is enabled under Video & Audio > Video Stream > Audio. Audio Modes The Axis product supports the following audio modes: Full duplex - Simultaneous two-way audio allowing the Axis product to transmit and receive audio at the same time. There is no echo cancellation; if feedback loops appear, try moving the microphone or the speaker.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Set the required Bit rate depending on the selected encoding. A higher bit rate will give better audio quality. A lower bit rate may have latency or delay, but will require less bandwidth. For more information about these settings, please see the online help . Audio Output Configure the audio output settings under Video & Audio > Audio Settings. Output gain - Control the volume (dB Full Scale) of the line audio output.
AXIS P5414–E PTZ Dome Network Camera Configure the Live View Page Configure the Live View Page You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page. • Stream Profile. See page 20. • Default Viewer for Browser. See page 26. • Viewer Settings. See page 27. • Action Buttons. These are the buttons described in Controls on the Live View Page on page 11 . • User Defined Links. See page 27. • Output Buttons.
AXIS P5414–E PTZ Dome Network Camera Configure the Live View Page Browser Viewer Description Windows Internet Explorer AMC Recommended viewer in Internet Explorer (H.264/Motion JPEG). QuickTime H.264. Java applet A slower imaging alternative to AMC (Motion JPEG). Requires one of the following installed on the client: • JVM (J2SE) 1.4.2 or higher. • JRE (J2SE) 5.0 or higher. Still image Displays still images only. Click the Refresh button in your browser to view a new image.
AXIS P5414–E PTZ Dome Network Camera Configure the Live View Page - Pulse activates the output for a defined period of time. The pulse time can be set from 1/100 second to 60 seconds. - Active/Inactive displays two buttons, one or each action. To configure the active and inactive states, go to System Options > Ports & Devices > I/O Ports and set the port’s Normal state. For more information about I/O ports, see I/O Ports on page 54.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) PTZ (Pan Tilt Zoom) Preset Positions A preset position is a saved view that can be used to quickly steer the camera to a specific position. A preset position consists of the following values: • Pan and tilt positions • Zoom position • Focus position (manual or automatic) Focus Window The focus window makes it possible to select an area of the camera's image that focus should be applied on.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) 2. Enter a descriptive name. 3. Specify the pause length between runs. 4. Select an available preset position and click Apply. 5. Specify the Move Speed. 6. Specify the View Time in seconds or minutes. 7. Specify the View Order or select the Random view order option. 8. Click Save. To modify or remove guard tours, go to PTZ > Guard Tour, select the guard tour in the Guard Tour List and click Modify/Remove. For more information see the online help .
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) x Move speed sets the speed of the camera’s pan and tilt movements. The default setting is maximum speed. When using a joystick (or emulating one with the mouse) the Enable proportional speed setting can be used to reduce the maximum pan/tilt movement speed, i.e. the speed the camera view moves at when the joystick is pushed all the way out in any direction. This is useful then the view is zoomed in on an object.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) A user who belongs to a group (see Users on page 45) with a higher PTZ priority can go before other users in the queue and take control of the product. The order of priority is as follows: 1. Administrator — An administrator takes over PTZ control regardless of who is first in queue. The administrator will be removed from the queue 60 seconds after the last PTZ control command. 2.
AXIS P5414–E PTZ Dome Network Camera Detectors Detectors Motion Detection Motion detection is used to generate an alarm whenever movement starts or stops in the camera view. Motion detection is configured by defining up to 10 Include and Exclude windows: • Include windows — define areas where motion should be detected • Exclude windows — define areas within an Include window that should be ignored (areas outside Include windows are automatically ignored).
AXIS P5414–E PTZ Dome Network Camera Detectors Motion Detection Parameters The parameters controlling motion detection are described in the table below: Parameter Object Size History Sensitivity Description Object size relative to window size. Object memory length. Difference in luminance between background and object. High level (100%) Only very large objects trigger motion detection.
AXIS P5414–E PTZ Dome Network Camera Applications Applications Third party applications can be uploaded to and installed on the Axis product. Applications add functionality to the product, for example video analytics and intelligent video capabilities such as recognition, tracking, detection and counting. For information about available applications, downloads, trials and licenses, go to www.axis.com/applications Note • It is recommended to run one application at a time.
AXIS P5414–E PTZ Dome Network Camera Applications If the Axis product is reset to factory default, installed applications and their settings are removed. For information about factory default, see Reset to Factory Default Settings.
AXIS P5414–E PTZ Dome Network Camera Events Events The Event pages allow you to configure the Axis product to perform actions when different events occur. For example, the product can start a recording or send an email notification when motion is detected. The set of conditions that defines how and when the action is triggered is called an action rule. Convert Event Types to Action Rules If the Axis product is upgraded to firmware version 5.
AXIS P5414–E PTZ Dome Network Camera Events For more information, see the online help . Triggers Available action rule triggers and conditions include: • Applications – Use installed applications to trigger the rule. See Applications on page 35. • Detectors • • • • • - Audio Detection – Trigger the rule when audio is detected. See Audio Detection on page 34. - Day/Night Mode – Trigger the rule when the product switches between day mode (IR cut filter on) and night mode (IR cut filter off).
AXIS P5414–E PTZ Dome Network Camera Events • Time - Recurrence – Trigger the rule periodically. See Set Up Recurrences on page 41. This can for example be used to upload an image every 5 minutes. - Use Schedule – Trigger the rule according to the selected schedule. See Create Schedules on page 41. Actions Available actions include: • Day/Night Vision Mode – Set day mode (IR cut filter on) or night mode (IR cut filter off). • Output Port – Activate an I/O port to control an external device.
AXIS P5414–E PTZ Dome Network Camera Events Recipient Use with action Notes Email Send Images An email recipient can contain multiple email addresses. For more information about email recipients, see Set Up Email Recipients on page 40 Send Notification Send Video Clip FTP Send Images Send Video Clip HTTP Send Images Send Notification Send Video Clip HTTPS Encrypted file transfer using HyperText Transfer Protocol Secure (HTTPS).
AXIS P5414–E PTZ Dome Network Camera Events Create Schedules Schedules can be used as action rule triggers or as additional conditions, for example to record video if motion is detected outside office hours. Use one of the predefined schedules or create a new schedule as described below. To create a new schedule: 1. Go to Events > Schedules and click Add. 2. Enter a descriptive name and the information needed for a daily, weekly, monthly or yearly schedule. 3. Click OK.
AXIS P5414–E PTZ Dome Network Camera Recordings Recordings The Axis product can be configured to record video continuously or according to an action rule: • To start a continuous recording, see page 42. • To set up action rules, see page 37. • To access recordings, see Recording List on page 42. • To configure camera controlled storage, see Storage on page 53. Recording List Recorded videos are listed on the Recordings > List page.
AXIS P5414–E PTZ Dome Network Camera Recordings 5. Click Save to save and start the recording.
AXIS P5414–E PTZ Dome Network Camera Languages Languages Multiple languages can be installed in the Axis product. All web pages including the online help will be displayed in the selected language. To switch languages, go to Setup > Languages and first upload the new language file. Browse and locate the file and click the Upload Language button. Select the new language from the list and click Save.
AXIS P5414–E PTZ Dome Network Camera System Options System Options Security Users User access control is enabled by default and can be configured under System Options > Security > Users. An administrator can set up other users by giving them user names and passwords. It is also possible to allow anonymous viewer login, which means that anybody may access the Live View page.
AXIS P5414–E PTZ Dome Network Camera System Options 2. Select an HTTPS certificate from the list of installed certificates. 3. Optionally, click Ciphers and select the encryption algorithms to use for SSL. 4. Set the HTTPS Connection Policy for the different user groups. 5. Click Save to enable the settings. To access the Axis product via the desired protocol, enter https:// or http:// in the address field in a browser. The HTTPS port can be changed on the System Options > Network > TCP/IP > Advanced page.
AXIS P5414–E PTZ Dome Network Camera System Options To install a self-signed certificate: 1. Go to Setup > System Options > Security > Certificates. 2. Click Create self-signed certificate and provide the requested information. To create and install a CA-signed certificate: 1. Create a self-signed certificate as described above. 2. Go to Setup > System Options > Security > Certificates. 3. Click Create certificate signing request and provide the requested information. 4.
AXIS P5414–E PTZ Dome Network Camera System Options Network Basic TCP/IP Settings The Axis product supports IP version 4 and IP version 6. Both versions can be enabled simultaneously, and at least one version must always be enabled. IPv4 Address Configuration By default, the Axis product is set to use IPv4 (IP version 4) and to obtain the IP address automatically via DHCP. The IPv4 settings are configured under System Options > Network > TCP/IP > Basic.
AXIS P5414–E PTZ Dome Network Camera System Options ping -l 408 -t Windows example (this may require that you run the command prompt as an administrator) arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125 4. Check that the network cable is connected and then restart the product by disconnecting and reconnecting power. 5. Close the command prompt when the product responds with Reply from 192.168.0.125:... or similar. 6.
AXIS P5414–E PTZ Dome Network Camera System Options Domain name - Enter the domain(s) to search for the host name used by the Axis product. Multiple domains can be separated by semicolons. The host name is always the first part of a fully qualified domain name, for example, myserver is the host name in the fully qualified domain name myserver.mycompany.com where mycompany.com is the domain name. Primary/Secondary DNS server - Enter the IP addresses of the primary and secondary DNS servers.
AXIS P5414–E PTZ Dome Network Camera System Options Note • For NAT traversal to work, this must be supported by the router. The router must also support UPnPTM. • In this context, router refers to any network routing device such as a NAT router, Network router, Internet Gateway, Broadband router, Broadband sharing device, or a software such as a firewall. Enable/Disable - When enabled, the Axis product attempts to configure port mapping in a NAT router on your network, using UPnPTM.
AXIS P5414–E PTZ Dome Network Camera System Options SMTP (email) To send email messages from the Axis product via SMTP (Simple Mail Transfer Protocol), an SMTP mail server must be set up. This is done under System Options > Network > SMTP (email). Enter the host names or IP addresses and port numbers for the primary and secondary mail servers in the fields provided. A From email address is also required.
AXIS P5414–E PTZ Dome Network Camera System Options Bonjour The Axis product includes support for Bonjour. Bonjour is enabled by default and the product is automatically detected by operating systems and clients that support this protocol. Bonjour can be disabled under System Options > Network > Bonjour. Storage SD Card NOTICE TICE NO To prevent corruption of recordings, the SD card should always be unmounted before it is ejected. Note For SD card recommendations see www.axis.
AXIS P5414–E PTZ Dome Network Camera System Options To clear all recordings and data from the Axis product’s folder on the designated share, click Clear under Storage Tools. To avoid filling the share, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings older than and select the number of days or weeks. To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
AXIS P5414–E PTZ Dome Network Camera System Options Support Support Overview The System Options > Support > Support Overview page provides information on troubleshooting and contact information, should you require technical assistance. See also Troubleshooting on page 58. System Overview To get an overview of the Axis product’s status and settings, go to System Options > Support > System Overview.
AXIS P5414–E PTZ Dome Network Camera System Options File Upload Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload. Uploaded files are accessed through http:///local// where is the selected user group (viewer, operator or administrator) for the uploaded file. Plain Config Plain Config is for advanced users with experience of Axis product configuration.
AXIS P5414–E PTZ Dome Network Camera Repainting the Camera Repainting the Camera The covers can be repainted to match the installation environment. The material used in the covers is ASA Geloy XTWM206. Use paint suitable for this material. 1. Remove the two top cover screws. 2. Use a thin palette knife to release the locking tabs while pulling the top cover straight upwards to remove the cover. 3. Remove the two bottom cover screws and remove the bottom cover. 4.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Troubleshooting Check the Firmware Firmware is software that determines the functionality of network devices. One of your first actions when troubleshooting a problem should be to check the current firmware version. The latest version may contain a correction that fixes your particular problem. The current firmware version in the Axis product is displayed in the page Setup > Basic Setup and in Setup > About.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Emergency Recovery Procedure If power or network connection is lost during the upgrade, the process fails and the product becomes unresponsive. Flashing red Status indicator indicates a failed upgrade. To recover the product, follow the steps below. The serial number is found on the product’s label. 1.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting The IP address has been changed by DHCP IP addresses obtained from a DHCP server are dynamic and may change. If the IP address has been changed, use AXIS IP Utility or AXIS Camera Management to locate the product on the network. Identify the product using its model or serial number, or by the DNS name (if the name has been configured). If required, a static IP address can be assigned manually.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Lower frame rate than expected See Performance Considerations on page 67. Reduce the number of applications running on the client computer. Limit the number of simultaneous viewers. Check with the network administrator that there is enough bandwidth available. Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only key frames. Lower the image resolution.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Video cannot be recorded Check that the SD card is not write protected (that is, read only). SD card cannot be mounted Reformat the SD card and then click Mount. NOTICE TICE NO Formatting the card will remove all content, including all recordings, from the SD card.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Technical Specifications Function/group Item Specifications Camera Models AXIS P5414–E 50 Hz AXIS P5414–E 60 Hz Image sensor 1/2.8” progressive scan RGB CMOS Lens f=4.7 mm – 84.6 mm F1.6 — 2.8 Autofocus Automatic day and night functionality Horizontal angle of view: 59° — 4° Vertical angle of view: 35° – 2° Minimum illumination Color: 0.4 lux at 30 IRE F1.6 B/W: 0.04 lux at 30 IRE F1.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Function/group Item Specifications Network Security Password protection, IP address filtering, HTTPS encryption*, IEEE 802.1X network access control*, digest authentication, user access log *This product includes software developed by the Open SSL Project for use in the Open SSL Toolkit (www.openssl.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Function/group Item Specifications Operating conditions Temperature: –20 °C to 50 °C (–4 °F to 122 °F) Humidity 10–100% RH (condensing) Approvals EN 50121–4, IEC 62236–4, EN 55022 Class B, EN 61000-6-1, EN 61000-6-2, EN 55024, FCC Part 15 Subpart B Class B, ICES-003 Class B, VCCI Class B, C-tick AS/NZS CISPR 22 Class B, KCC KN22 Class B, KN24, IEC/EN/UL 60950-1, IEC/EN/UL 60950-22, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-1
AXIS P5414–E PTZ Dome Network Camera Technical Specifications 1 12 V max 50 mA 2 3 4 3. 4. I/O configured as input I/O configured as output Power Connector 2-pin terminal block for power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications 1 Tip Audio Input 2 Ring 3 Sleeve Ground Microphone/Line in SD Card Slot Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10. Performance Considerations When setting up your system, it is important to consider how various settings and situations will affect performance.
User Manual AXIS P5414–E PTZ Dome Network Camera © Axis Communications AB, 2013–2014 Ver. M3.2 Date: November 2014 Part No.