User`s manual

AXIS P7214 Video Encoder
System Options
The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Conguration.
The Access Log can be congured to list a ll connections to the product (se lect Critica l, W arning s & Info). I f require d, a differ ent log
level can be used when sending emails.
Advanced
Scripting
Scripting allow s experienced users to customize and use their own scripts.
NOTICE
Improper use may cause unexpected behavior and loss of contact with the Axis product.
Axis strongly recomm ends that you do not use this function unless you understand the consequences. Axis Support does not provide
assistance for problems with customized scripts.
To open the Script Ed itor, go to System Options > Advanced > Scripting. It is recommended to create a backup le before
customizing the scripts. If a script cause s problems, reset the product to its factory default settings, se e
page 44
.
For more information, see www.axis.com/developer
File Upload
Files, for example web page s and images, can be uploaded to the Axis product a nd used as custom settings. To upload a le, go
to System Options > Advanced > File Upload.
Uploaded les are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or a dministrator) for the up loaded le.
Plain Cong
Plain C ong is for advanced users with experience of Axis product conguration. Most parameters can be set and modied from this
page. Help is available from the standard help pages.
To open Plain Cong, go to Sy stem O p tion s > Advan c ed > Plain Cong .
Reset to Factory Default Settings
This will reset all pa rameters, including the IP address, to the fac tory default settings:
1. Disconnect power from the product.
2. Press and ho ld the C ontrol button and reconnect power (see
Hardware Overview, on page 4
).
3. Keep the C ontrol b u tton pressed for about 15 seconds until the Status indicator ashes amber.
4. Release the Control button. The pro cess is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The d efault IP address is 192.168.0.90
5. Re-assign the IP address.
It is also possible to reset parameters to fa ctory default via the web interface. Go to Setup > System Options > Maintenance.