User manual
AXIS P7224
Hardware overview
• ConnectingtoanAXISVideoHostingSystemservice.Seepage 33. To connect, p ress and hold the button for about
1 second until the Status LED flashes gree n.
• ConnectingtoAXISInternetDynamicDNSService. Seepage 33. To connect, press and hold the button for
about 3 seconds.
• Resetting the product to factory default settings. See page 39.
Restart button - Press to restart the product.
Pin Assignments for I/O Connector - AXIS 291 1U Video Server Rack
Pin Function Description
1
+12V out,
100mA
2
GND
3
Configurable
I/O 1
4
Configurable
I/O 2
5
Configurable
I/O 3
6
Configurable
I/O 4
Digital input - Connect to GND to activate, or leave
floating (or unconnected) to deactivate.
Digital output - Uses an opendrain NFET transistor
with the source connected to GND. If used with
an external relay, a diode must be connected
in parallel with the load, for protection against
voltage transients.
Min input = 0V DC
Max input = + 40V DC
Max load = 100mA
Max voltage applied = + 40V DC
7–
10
Not used
11
RS485A
12
RS485B
A half-duplex RS-485 interface for controlling auxiliary e quipment e.g. PTZ devices.
Pin Assignments for I/O Connector - AXIS Q7900 Rack
Pin Function Description
1
Configurable
I/O 1
2
Configurable
I/O 2
3
Configurable
I/O 3
4
Configurable
I/O 4
Digital input - Connect to GND to activate, or leave
floating (or unconnected) to deactivate.
Digital output - Internal connection to ground
when activated, floating (unconnected) when
deactivated. If used with an external relay, a diode
must be connected in parallel with the load, for
protection against vo ltage transients.
Min input = 0V DC
Max input = + 40V DC
Max load = 100mA
Max voltage applied = + 40V DC
5–
12
Not used