INSTALLATION GUIDE AXIS T8125 AC 24 V Midspan 60 W ENGLISH
Legal Considerations Australia - This digital equipment fulfills the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22. Electromagnetic Compatibility (EMC) Korea - ࢇ ̛̛Е ɼࢽࡈ %̗ ࢷળࢶଢ̛̛Ի۰ ࣯Ի ɼࢽ߾۰ ࡈیଜЕ ʨࡶ ּࢶࡳԻ ଜֲ ֻҘ एࠇ߾۰ ࡈیଟ ܹ ݡТЬ Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before using this product for surveillance purposes.
Support Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can: • download user documentation and software updates • find answers to resolved problems in the FAQ database.
Safeguards Please read through this Installation Guide carefully before installing the product. Keep the Installation Guide for further reference. • • • • • • • • Store the Axis product in a dry and ventilated environment. Avoid exposing the Axis product to vibration, shocks or heavy pressure and do not install the camera on unstable brackets, unstable or vibrating surfaces or walls, since this could cause damage to the product.
AXIS T8125 AC 24 V Midspan 60 W Page 7 AXIS T8125 AC 24 V Midspan 60 W Installation Guide Safety Information AC Power inlet set: • The 24 V AC power source must be near the AXIS T8125 and easily accessible. To remove AC power from the AXIS T8125, disconnect the 24 V AC power inlet from either the 24 V AC power source or the AXIS T8125 power connector. • The AXIS T8125 DATA IN and DATA & POWER OUT interfaces are qualified as SELV (Safety Extra-Low Voltage) circuits according to IEC 60950-1.
Page 8 AXIS T8125 AC 24 V Midspan 60 W Caution! • Read the Installation Guide and the Safety Information before connecting the AXIS T8125 to its power source. • Follow basic electricity safety measures when connecting the AXIS T8125 to its power source. • A voltage mismatch can cause equipment damage and may pose a fire hazard. If the voltage indicated on the label is different from the power outlet voltage, do not connect the AXIS T8125 to this power outlet.
AXIS T8125 AC 24 V Midspan 60 W Page 9 Functions and Features • Alt A: pins 1, 2 (-) & 3, 6 (+) • Alt B: 4, 5 (+) and 7, 8 (-) Preliminary Steps • Ensure that 24 V AC is applied to the AXIS T8125. Use cables of 12 AWG for each terminal or 2X16 AWG for each terminal, with an appropriate separate ground connection (when needed). • Ensure that the output Ethernet cable is connected to the DATA & POWER OUT port. • Verify that a power-ready Ethernet compatible device is connected.
Page 10 AXIS T8125 AC 24 V Midspan 60 W Installing the Unit 1. 2. 3. 4. 5. 6. Verify that the 24 V AC power source is turned off. Connect cables to the AXIS T8125 Input terminal connector (12 AWG for each terminal or 2X16 AWG for each terminal). After connecting the cables to the terminal connector securely tighten all 4 connector screws. See Figure 3. Connect the cables from the data switch's patch panel to the Input Ethernet port (DATA IN). See Figure 4.
AXIS T8125 AC 24 V Midspan 60 W LINE Page 11 NEUTRAL 2x cable inlet screws ENGLISH Figure 2 Chassis 24 AC Input connection terminal block 2x connector screws Terminal connector Figure 3 AC input connectivity indication (Main LED) Figure 4 Port connectivity indication (Port LED) Output Input terminal port terminal port (DATA & POWER OUT) (DATA IN)
Page 12 AXIS T8125 AC 24 V Midspan 60 W Indicators Main LED Green OFF Power OFF indication Port LED Green Power ON indication (power is active) OFF Behavior Disconnected.
AXIS T8125 AC 24 V Midspan 60 W Page 13 Ethernet Interface RJ45 female socket Input (DATA IN) RJ45 female socket, with DC Output (DATA & POWER OUT): voltage on wire pairs 1-2, 3-6, 4-5 Ethernet 10/100/1000Base-T, plus 55 V DC & 7-8. ENGLISH Troubleshooting Symptom Corrective Steps 1. The AXIS T8125 2. does not power up. 3. 1. 2. A port indicator is 3. not lit and the 4. AXIS T8125 does not operate 5. 6. 7. 1. 2. The end device operates, but there 3. is no data link 4. 5.
Page 14 AXIS T8125 AC 24 V Midspan 60 W Warranty For information about Axis' product warranty and thereto related information, see www.axis.
Installation Guide AXIS T8125 AC 24 V Midspan 60 W © Axis Communications AB, 2012-2013 Ver.1.0 Printed: March 2013 Part No.