Installation guide

AXIS T8125 AC 24 V Midspan 60 W Page 7
ENGLISH
AXIS T8125 AC 24 V Midspan 60 W
Installation Guide
Safety Information
AC Power inlet set:
• The power connector supplied with the AXIS T8125 has 2
terminals; LINE (L) and NEUTRAL (N). See Figure 2.
• The power inlet cables must be rated for a minimum current
capacity of 6 amps (12 AWG for each terminal or 2X16 AWG for
each terminal).
• Before connecting power inlet cables to the connector terminals,
verify that the power source is turned OFF.
• Only for improved EMI performance, connect chassis ground
connection to "Earth Ground" connection at the working area.
Note: There is no safety hazard when the chassis ground
connection is not connected to the “Earth Ground”.
• The 24 V AC power source must be near the AXIS T8125 and easily
accessible. To remove AC power from the AXIS T8125, disconnect
the 24 V AC power inlet from either the 24 V AC power source or
the AXIS T8125 power connector.
• The AXIS T8125 DATA IN and DATA & POWER OUT interfaces are
qualified as SELV (Safety Extra-Low Voltage) circuits according to
IEC 60950-1. These interfaces can only be connected to SELV
interfaces on other equipment.
Note: The AXIS T8125 "DATA IN" and "DATA & POWER OUT" ports
are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) sockets. Only RJ45 data
connectors may be connected to these sockets.