INSTALLATION GUIDE ENGLISH AXIS T8133 Midspan 30W
Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Communications AB cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and manuals without prior notice.
• Consult the dealer or an experienced radio/TV technician for help. Canada This Class B digital apparatus complies with Canadian ICES-003. Europe This digital equipment fulfills the requirements for RF emission according to the Class B limit of EN 55022. This product fulfills the requirements for immunity according to EN 55024 office and commercial environments Australia/New Zealand This digital equipment fulfills the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22.
AXIS T8133 Midspan 30W Safety Information Hazard Levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a situation which, if not avoided, could result in damage to property.
AXIS T8133 Midspan 30W Safety Instructions WARNING • The Axis product shall be installed by a trained professional. NOTICE • The Axis product shall be used in compliance with local laws and regulations. • To use the Axis product outdoors, or in similar environments, it shall be installed in an approved outdoor housing. • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis product to shocks or heavy pressure.
AXIS T8133 Midspan 30W Installation Guide Installation Steps 1. 2. 3. 4. Make sure the package contents, tools and other materials necessary for the installation are in order. See page 7 . Study the hardware overview. See page 8 . Study the specifications. See page 8 . Install the hardware. See page 10.
AXIS T8133 Midspan 30W Hardware Overview 2 1 1 2 3 3 Port LED indicator DATA & POWER OUT DATA IN Indicators Port LED Indicated Behavior Yellow On Power is on (power is active) Green On A remote terminal is connected Green Blinking Overload state or short-circuit Specifications Operating Conditions The Axis product is intended for indoor use.
AXIS T8133 Midspan 30W Temperature Humidity Operating -20 °C to 40 °C (-4 °F to 104 °F) 10-90% RH (non-condensing) Mode Temperature Humidity Storage -20 °C to 70 °C (-4 °F to 158 °F) 10-90% RH (non-condensing) Storage Conditions Power Consumption Input Voltage 100 — 240 V AC 50/60 Hz Maximal Input Current 0.8 Ampere Available Output Power (max) 30 Watts Nominal Output Voltage 55 V DC Power over Ethernet Plus (PoE+) IEEE 802.
AXIS T8133 Midspan 30W Connectors and Buttons For specifications and operating conditions, see page 8 . Network Connector RJ45 Ethernet connector. Supports Power over Ethernet (PoE). NOTICE The product shall be connected using a shielded network cable (STP). All cables connecting the product to the network switch shall be shielded (STP) and intended for their specific use. Make sure that the network switch is properly grounded.
AXIS T8133 Midspan 30W 2 1 3 ENGLISH 1 2 3 Port LED indicator DATA & POWER OUT (connect to Axis product) DATA IN (connect to network) NOTICE • Do not cover the midspan or block the airflow to the PoE with any foreign objects. Keep the midspan away from excessive heat and humidity and free from vibration and dust. • Ensure that the cable length from Etherhet network source to the terminal does not exceed 100 m (330 ft). The PoE is not a repeater and does not amplify the Ethernet data signal.
AXIS T8133 Midspan 30W • Verify that the voltage at the power inlet is between 100 — 240 V AC. • Verify that the power inlet cable is functional. The powered device does not operate • • Verify that the powered device is designed for PoE operation. Verify that a standard Category 5/5e/6, straight-wired cable with four pairs is used. • Verify that the input Ethernet cable is connected to the DATA IN port. • Verify that the powered device is connected to the DATA & POWER OUT port.
Installation Guide AXIS T8133 Midspan 30W © Axis Communications AB, 2013 Ver. M1.14 Date: October 2013 Part No.