Instruction manual
Assembly Instructions
13
Step 20 Locate the manometer and hose (16), remove the 
fixings from the lower leg square tube (2), offer up the two 
pre-drilled holes in the manometer (16) with the holes in 
the leg (2), replace the fixing and tighten. (see fig 38)
NOTE: MAKE SURE THE MANOMETER (16) IS 
MOUNTED TO THE LEFT SIDE OF THE LEG!
Fig 38
Step 21 Place a small Jubilee (j) over one end of the 
hose and insert it over the small outlet manifold on the 
extraction funnel (11) and nip up tight, see fig 39.
Fig 39
WARNING! DONT OVERTIGHTEN THE JUBILEE 
CLIP TO PREVENT THE HOSE FROM SPLITTING!
j
Hose
2
16
Step 22 Connect the other end of the hose to the inlet 
manifold to the rear of the manometer (16), see fig 40.
Fig 40
j
Step 23 Locate the inlet moulding (13) and the 12unc 
screw (i). Insert the moulding over the outlet manifold 
on the extraction funnel (11), line up the pre-drilled 
holes and secure using the 12unc screw and Phillips 
screw driver, see fig 41.
Fig 41
13
11
i
Step 24 Finally go round and make sure all fixings are 
tight and secure.
CONNECT THE POWER SUPPLY TO THE MAINS 
AND SWITCH ON!
DISCONNECT THE POWER SUPPLY FROM THE 
MAINS!
Wait until it’s up to full speed and check for signs of 
vibration, if all is well.. switch off and wait until the 
extractor has come to a compleate stop!
If the extractor fails to start up or any other strang 
noises apart from vibraction sounds, contact the 
“Technical Sales” for support.
Phone: 03332 406406 
Email: technical@axminster.co.uk
Testing the extractor
WARNING!! MAKE SURE CHILDREN ARE KEPT 
AWAY FROM THE CYCLONE EXTRACTOR WHILE 
IN OPERATION
NOTE: ALWAYS TURN ON/OFF THE EXTRACTOR 
BY THE NVR CONTROL SWITCH NOT THE MAINS 
SWITCH!