User's Manual

Table Of Contents
U-NII Config & User Guide 5.2 Axxcelera Broadband Wireless
13.11.2 Six-Sector, Six-Frequency Plan
This plan is good for Microcells or Macrocells on uneven terrain:
Use 1 channel guardband/separation between sectors
Use opposite polarization in opposite directions
Use 4 meter separation (or equivalent isolation)
Use >1 meter separation between sectors
Use a different set of three frequencies on alternating cells.
Single closest
interfering sector
61
3
2
4
5
6 Frequency Reuse
f1
f2
f3
HP
VP
f4
f5
f6
Sector
Numbering
Single closest
interfering sector
61
3
2
4
5
6 Frequency Reuse
f1
f2
f3
HP
VP
f4
f5
f6
Sector
Numbering
13.12 Antenna Spacing
In most Base Station deployments, multiple APs are placed on a single building or tower.
To minimize AP to AP interference, it is necessary to mount the antennas with proper spacing.
Based on the frequency plan identified, the following minimum spacing shown in the table
below should be maintained.
March 10, 2003 Company Confidential Page 143 of 149