User's Manual

Table Of Contents
EXCELMAX ACCESS POINT CELL INSTALLATION AND MAINTENANCE GUIDE VERSION 1.4
17
OF 65
3.2.3 FCC Label @ FCC 15.19
For Class B - Unintentional Radiators:
This device complies with Part 15 of the FCC Rul
es. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference and (2) this device must accept any
interference received, including interference that may cause undesired operation.
3.2.4 RF EXPOSURE REQUIRMENTS @ 1.1310 & 2.1091
3.3 Installation Warnings
Please pay attention to the following
warnings:
When servicing equipment and selecting a location for
the ExcelMAX antennas, it is important to
note that a minimum distance of 25 cm is required between personnel and ExcelMAX antennas to
comply with a radio-frequency exposure limit of 1.0mW/cm2.
Figure 3-9: RF Warning Label
Arcing may occur when connecting the outdoor Ethernet cable to either the Access Point or the
NIA should the power be connected to the NIA. Arcing may irrevocably damage the NIA or the
Access Point. To prevent any chance of damage from occurring, verify that the power is
disconnected from the NIA before attempting to connect the interconnecting cable to either the
Access Point or NIA.
3.4 Environmental Cautions
Amb
ient Temperature – The BTS equipment (indoor equipment) must be installed in a
temperature-controlled environment. Ambient temperature should be within a temperature
range of -5 C to +40 C. The TMAs and antennas are outdoor equipment that are designed to
operate over a temperature range of -33 C to +55 C.
Relia
ble Grounding – Reliable grounding of the equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch
circuit (e.g. use of power strips).
Warning
T
o satisfy FCC RF exposure requirements for transmitting devices, a separation
distance of 25 cm or more should be maintained between the antenna of this
device and persons during device operation. To ensure compliance, operations at
closer than this distance is not recommended.
The antenna used for this transmitter must not be co-located in conjunction with
any other antenna or transmitter
°
°
°
°