3.7 Installing Optional Omnidirectional Antenna
3.7.1 Grounding the Antenna Mounting
1) Attach the ground lug using the Hex bolt, lock washer and flat washer that came with the
Access Point.
2) Ensure the cable has a good connection. Remove all paint and corrosion where the clamp is
attached.
3) Use dielectric grease on the clamp connection to prevent any electrolysis activity due to
dissimilar metals.
3.7.2 Installing the Omnidirectional Antenna
1) Attach the worm clamps to the omni bracket.
Figure 3-10: Attach worm clamps to Omni bracket
Warning
Do not work on antenna installations of any kind when there is any possibility of
electrical storm activity in the area.