User's Manual

Table Of Contents
EXCELMAX ACCESS POINT CELL INSTALLATION AND MAINTENANCE GUIDE VERSION 1.4
60
OF 65
Appendix A: NIA/Power Adapter Specifications: Model # TR60A-POE-L
Features Specifications
Universal Input: 90 ~ 264Vac
Continuous Short Circuit Protection
Conductive EMI Meets CISPR/FCC Class B
High Efficiency at 75% Minimum
Lighting Protection
NOTE 1: Voltage accuracy is set at 60% full load.
2: Add a 0.1uF ceramic capacitor and a 10uf
E.L. capacitor to output for Ripple & Noise
measuring @20MHz BW.
3: Line regulation is measured from 100Vac
to 240Vac with full load.
4: Load regulation is measured from 60% to
100% full load and from 60% to 20% full
load(60% +/- 40% full load).
In
put Characteristics
Voltage
Frequency
Inrush Current
Conducted EMI
Isolation
Leakage Current
90 ~ 264Vac
47 to 63Hz
50A Max. @ 264Vac
CISPR/FCC Class B
Input to output = 4,242Vdc
1.5mA max.
• Output Characteristics
Hold-up Time
Short Circuit Protection
Over Voltage Protection
8mS typ. @ 115Vac
Auto-Recovery
Auto-Recovery
• Environmental Characteristics
Operating Temperature
Storage Temperature
Operating Humidity
Cooling
0 ~ 40 C
-50 ~70 C
5% ~ 95%
Free air cooling
• Mechanical Outline
Dimensions 150mm x 70mm x 35mm
Typical at 25 C, nominal line and 75% load, unless otherwise Specified.
Model
Output
Voltage
Max.
Load
Min.
Load
Ripple &
Noise
Voltage
Accuracy
Line
Regulation
Load
Regulation
TR60A-POE-L 48 V 1.2 A 0 A 1% +/- 2% +/- 1% +/- 2%