User's Manual

Copyright 2015 Axxcelera Broadband Wireless, Inc. All rights reserved
AxxceLTE eNodeB
Installation Guide v1.0 - 8 -
Figure 3.3 eNodeB Deployment Scenarios (cont)
Depending on how you chose to deploy your BBU/RRH, the cabling can change greatly.
Below is a description of each interface on the eNodeB. Each interface is described with
its function, connector type and typical connection point on the other end of the cable.
This is a guide only and does not attempt to describe every possibility for connection
points.
3.1 Base Band Unit (BBU) Connections
Figure 3.4 - Panel Detail for Base Band Unit
GPS ANT:
· Used to connect to an external GPS receiver (included)
· Interface is a standard GPS with an SMA RF connector.
SYNCOUT:
· Used for synchronize to test and certification equipment. Should remain capped
when not in use. Can be configured to output one of several internal reference
signals. Please contact Axxcelera Support for more information if required.