ayon Typhon HC Triode Mono-Power Amplifier Owner’s Operating Manual Ayon Audio – Hart 18 – 8101 Gratkorn – Austria – Phone: +43 3124 24954 www.ayonaudio.
WARNING PRECAUTION AND SAFETY TO PREVENT SHOCK OR FIRE HAZARD DO NOT OPEN THE UNIT OR EXPOSE TO RAIN OR MOISTURE. REFER ALL SERVICE TO AYON AUDIO COMPANY OR AN AYON AUTHORIZED SERVICE FACILITY. THERE ARE NO USER SERVICEABLE PARTS INSIDE THE TYPHON. REFER ALL INTERNAL SERVICE, UPDATES, OR MODIFICATIONS TO QUALIFIED SERVICE PERSONNEL. HIGH VOLTAGE IS PRESENT INSIDE AN OPERATING TYPHON. DO NOT REMOVE BOTTOM PLATE OR INSERT ANY OBJECTS THROUGH OPENINGS IN THE CASE.
INTRODUCTION Thank you for your purchase of the Ayon Typhon power amplifier. Please read this owner’s manual to obtain the full benefit of the Typhon amplifier in your system. This manual provides you with necessary safety information and operation procedures for this unit. With this amplifier, you have entered into the world of exclusive design which will give you great satisfaction and privilege of enjoying the advanced technology of Ayon Audio products.
CONTENTS OPEN CARTON – UNPACKING THE TYPHON WHAT IS IN THE BOX OPERATION YOUR NEW TYPHON 1. 2. 3. 4. 5. 6. 7. 8. 9. Installation of tubes Connecting Turn ON procedure Turn OFF procedure Security caution in operation Grounding Bias adjustment Power tube – protection board Troubleshooting BREAK-IN PERIOD SPECIFICATION VACUUM TUBES WARRANTY AND SERVICE 4 Ayon Audio – Hart 18 – 8101 Gratkorn – Austria – Phone: +43 3124 24954 www.ayonaudio.
OPEN CARTON - UNPACKING THE TYPHON To avoid damaging the vacuum tubes please don’t turn the cardboard box upside down. Open the box and carefully take out the vacuum tubes and then the amplifier.
OPERATION 1. Installing the vacuum tubes Please remove the vacuum tubes and the Typhon from box and place the Typhon on a firm, level surface. Insert the vacuum tubes in accordance with the designated tube numbers into their relative assigned sockets. Note: It is very important to insert the tubes in the correct location. Important: Pay close attention to the direction of socket pins and their different diameter (6C33) of pins.
rear panel 1 2 3 4 5 6 7 8 9 input ( RCA or XLR ) speaker output terminal ( common , 4 Ohm or 8 Ohm ) potentiometer for bias adjustment: Bias 1 & Bias 4 bias meter selector ( Off, V1, V2, V3, V4 ) potentiometer for bias adjustment: Bias 2 & Bias 3 power inlet - with fuse toggle switch for RCA or Balanced mode phase indicating lamp - 230V Schuko only ground switch bottom plate Note: The power switch (on/off) is located at the front left corner of the bottom plate.
3. Turn ON procedure When all sources are connected properly, turn down the volume (preamp) to minimum, switch on the power - the Ayon-logo glows; it will go through a gentle power-on sequence first. Please wait for min. 60 seconds before turning the volume up. After 60 seconds, the unit is operational. Now you can increase the volume. Follow this procedure each time you turn your Typhon on. Some preamplifiers and sources can generate dangerous transients that can damage loudspeakers.
Note: NEVER REMOVE THE BOTTOM PLATE OF THE TYPHON BEFORE UNPLUGGING THE UNIT FROM THE WALL! 6. Grounding Make sure that Typhon monoblock’s are grounded to your wall ground first. If there is a hum loop (hum audible from more than a few inches from the loudspeakers) flip the grounded/ungrounded switch. If the hum doesn’t disappear then use a two prong plug to “float” one monoblock first and if it is necessary then “float” the second one too.
8. Power tube – protection board In order to protect the output level to the tubes, this unit is equipped with a special protection power tube circuit to detect over currents and voltages. When an over current or DC-input from the sources is detected or a power tube itself has a problem, the protection circuit will shut off the output tube’s current and continue to do so until the power is switched off.
SPECIFICATION Amplifier Class of Operation Tube Complement Load Impedance Negative Feedback Bandwidth Output Power Peak Output Power Input Impedance Input sensitivity for full power Gain S/N ratio at full power Hum Frequency Response Distortion at 1W Inputs Dimensions (WxDxH) cm Shipping dimensions (WxDxH) cm Weight per unit Shipping weight per unit Ayon Typhon PPP-HC Triode, Class A 4x 6C33*, 4 x 6H30 4 & 8 Ohms 0dB 10Hz-50kHz 80 Watt 120 Watt 100K Ohm 730mV 30.8 0.
WARRANTY AND SERVICE LIMITED WARRANTY Ayon Audio electronic components are warranted by the manufacturer to be free of defects in materials production for a period of 3 years (except all kinds of signal, rectifier and power tubes) from the date of purchase. Under this warranty defects are repaired free of charge. The purchaser is responsible for transportation from his location to the original sales agent, national distributor, or international distributor, whoever is closest.