INSTALLATION MANUAL---Selecting the Installation Place
Install the indoor unit level on a strong wall that is not
subject to vibrations.
The inlet and outlet ports should not be obstructed:the
air should be able to blow all over the room.
Do not install the unit near a source of heat , steam,or
flammable gas.
Install the unit near an electric socket or private circuit.
Do not install the unit where it will be exposed to
direct sunlight.
Install the unit where connection between indoor and
outdoor unit is as easy as possible.
Install the unit where it is easy to drain the condensed
water.
Check the machine operation regularly and leave the
necessary spaces as shown in the picture.
Install the indoor unit where the filter can be easily
accessible.
condensed water drain pipe
150
150
150
Sleeve
insulating covering
electrical cable
Mounting plate
Do not install the outdoor unit near sources of heat,
steam or flammable gas.
Do not install the unit in too windy or dusty places.
Do not install the unit where people often pass.Select
a place where the air discharge and operating sound
level will not disturb the neighbours.
Avoid installing the unit where it will be exposed
to direct sunlight ( other wise use a protection , if
necessary, that should not interfere with the air flow).
Leave the spaces as shown in the picture for the air to
circulate freely.
Install the outdoor unit in a safe and solid place.
If the outdoor unit is subject to vibration, fix rubber
gaskets onto it.
water drain pipe
300
500
2000
300
minimum space to be left (mm) showing
in the picture
500
Outdoor unit
Indoor unit
Pipe length is
15 meters Max.
be less than 5m
Height should
Outdoor unit
Indoor unit
Pipe length is
15 meters Max.
be less than 5m
Height should
Installation Diagram
15
INDOOR UNIT
OUTDOOR UNIT