Owner's Manual

Leak Check
WARNING
Perform all leak tests
outdoors.
Extinguish all open
flames.
NEVER leak test when smoking.
Do not use the fire pit until all connections have
been
leak tested and do not leak.
DANGER
NEVER USE A LIGHTER/FLAME TO CHECK FOR GAS
LEAKS.
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all fire pit and light valves are OFF.
5. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve OFF.
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles continue
appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak check. If you
continue to see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s place
of purchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test.
Complete installation.
14
Hose/Regulator
connection
Regulator/Cylinder
connection