6 Lightning Protection Installation
The lightning protector is to protect MSR4K44S to avoid damage by burst high
current from lightning. Lightning protector should be installed between radio port
and antenna feeder, and the lightning protector should be connected with lightning
system of the building .
Tools needed: Paper knife, Pliers, Crimping Pliers, Cross Screwdriver, and Spanners.
The procedure of lightning protector:
1 Connect the lightning protector to radio port of MSR4K44S;
2 Fasten the lightning protector by Spanner;
3 Unpack the copper ring of grounding.
4 Put the naked side of grounding wire into copper ring and pressed firmly by
Crimping Pliers;
5 Connect the grounding copper ring with lightning protector and fasten it by
Cross Screwdriver;
6 Connect the another side of grounding wire with grounding bar;
7 Daub butter on both side of grounding wire;
Lightning