3.5 Power up Timing Sequence
Power-up Sequence
VDDIO/Pdn no specific time requirement, just need to follow up the power on sequence waveform.
Power-down Sequence
The table is AW-CM358AN module power down sequence, the maximum ramp-down time for PDn
from VBAT assertion is 10ms.VBAT must be asserted a minimum of 100 ms to guarantee that PDn
are discharged to less than 0.2V for the POR generate properly after VBAT is deasserted.