Data Sheet

28
FORM NO.: FR2-015_ A Responsible DepartmentWBU Expiry Date: Forever
The information contained herein is the exclusive property of AzureWave and shall not be distributed, reproduced, or
disclosed in whole or in part without prior written permission of AzureWave.
2.6 RF exposure considerations
This equipment complies with FCC mobile radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20cm
between the radiator & your body. If the module is installed in a portable host, a separate SAR
evaluation is required to confirm compliance with relevant FCC portable RF exposure rules.
2.7 Antennas
The following antennas have been certified for use with this module; antennas of the same type
with equal or lower gain may also be used with this module. The antenna must be installed such
that 20 cm can be maintained between the antenna and users.
2.8 Label and compliance information
The final end product must be labeled in a visible area with the following: “Contains FCC ID: TLZ-
NM512”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.
2.9 Information on test modes and additional testing requirements
This transmitter is tested in a standalone mobile RF exposure condition and any co-located or
simultaneous transmission with other transmitter(s) or portable use will require a separate class II
permissive change re-evaluation or new certification.
2.10 Additional testing, Part 15 Subpart B disclaimer
This transmitter module is tested as a subsystem and its certification does not cover the FCC Part
15 Subpart B (unintentional radiator) rule requirement applicable to the final host. The final host
will still need to be reassessed for compliance to this portion of rule requirements if applicable.
As long as all conditions above are met, further transmitter test will not be required. However, the OEM
integrator is still responsible for testing their end-product for any additional compliance requirements
required with this module installed.