User's Manual

COAT015197 Instruction manual ONE-C EN
13
4.4 "USER PARAMETERS" - Settings for the program:
The "USER PARAMETERS" functions provides access to the list of user settings that can be modified
in order to adjust the barrier. Some of these settings can be accessed only via the "ADMIN" user.
Here is the list of default settings:
Settings
Description
Unit
OP
ADMIN
Type_barriere
Choice of the type of barrier to be
controlled:
1 : LBA4
2 : LBA6
3 : LBA6R
4 : LBA63PK
5 : LBA63PG Aval
6 : LBA63PG Amont
7 : LBA7
8 : LBA7R
9 : LBA74
10 : LBA86NEO IR
11 : LBA86NEO R
12 : LBA12
A restart of the barrier is
mandatory after any change to this
setting.
Longueur_lisse
Length of the arm.
m
Grille_lisse
Type of grid:
0 : No grid
1 : GA grid
2 : GTH grid
3 : HP grid
Boost_Vit_1
Boost applied at opening speed (default
mode: 100%)
%
Boost_Vit_2
Boost applied at closing speed (default
mode: 100%)
%
T_manoeuvre
The time beyond which the barrier goes
into
default mode if neither of the two limit
switches has been detected. (default
mode: 30s)
s
FAT
Activation of automatic closing after
time delay
(TRUE: enabled; FALSE: disabled).
FAP
Activation of automatic closing after
passing through the safety loop (TRUE:
activated; FALSE: deactivated).
T_FAT
Waiting time before automatic closing
after timer (if enabled) (default mode:
15s)
s
T_FAP
Waiting time before the automatic closing
after passage (if activated)
(default mode: 0s)
s