User's Manual

COAT015197 Instruction manual ONE-C EN
15
signalling elements (LED cover,
illuminated rail) during the moving
phase.
(TRUE: On; FALSE: Off).
Cligno_orange
Activation of the flashing of the
signalling elements (LED cover,
illuminated rail) during the orange
lighting phase.
(TRUE: On; FALSE: Off).
Cligno_rouge
Activation of the flashing red light (or
LED cover/illuminated cover during the
red light up phase)
(TRUE: On; FALSE: Off).
Veille_Vert
Activation of the automatic green
light extinction (or led/illuminated
cover during the green light phase)
(TRUE: On; FALSE: Off).
T_Veille_Vert
Time after which the green light (or
LED cover/illuminated shield during
the green light up phase) goes out if
the parameter
"Green_Sleep" is activated. (default
mode: 60s)
s
English
Passing messages into French
(TRUE: English; FALSE: French).
Regondage_auto
Activating the automatic rewind function
(LBA63PG)
(TRUE: On; FALSE: Off).
Reouverture_secu
Activation of automatic reopening on
detection of a safety device (loops,
infrared cell, ultrasound, etc.).
(TRUE: enabled; FALSE: disabled)
Etat_apprentissage
A variable that allows you to visualise
whether teach-in has been achieved
through the barrier or not.
(TRUE: achieved; FALSE: not achieved)
Butee_1
Value of the opening stop recorded
during training
°
Tolerance_1
Tolerance angle around the stop
opening in which the barrier is considered
to be open. (default mode: +/-5°)
°
Butee_2
Value of the closing stop recorded during
training
°
Tolerance_2
Tolerance angle around the closing stop
in which the barrier is
considered closed. (default mode: +/-5°)
°
Offset_Ouv
Size of the idle range once the
Slowing down completed before reaching
the opening end stop (default mode: 0°)
°
Offset_Ferm
Size of the idle range after deceleration
before reaching the closing end stop
(default mode: 0°)
°