User's Manual

COAT015197 Instruction manual ONE-C EN
20
4.8 "LOCATED VARS" - Local variables of the program:
The "LOCATED VARS" tab provides access to the statuses of the local variables of the barrier for the
purposes of troubleshooting, for example. This function can be accessed only with the ADMIN profile
(See §4.1. Choice of the user)
Here is the list of available variables:
Variable
Description
Commande_Ouverture
Possibility of maintaining an open control (NO)
Commande_Fermeture
Possibility of maintaining a close control (NO)
Etat_commande_ouverture_GTC
CTM opening control status (NO)
Etat_commande_fermeture_GTC
CTM closing command status (NO)
Etat_Detection_Boucle_Securite
Safety loop status (NO)
Etat_Detection_Cellules
Ultrasound or infrared cell status (NO)
Etat_Boucle_Ouverture_Libre
Free opening loop status (NO)
Etat_Mode_Auto
Auto/Man mode status (0=Manual mode; 1=Auto mode)
Etat_Capteur_Degondage
Unhinging sensor status (NC)
Etat_Capteur_Fdc_Ouv
Opening end-of-travel sensor status (NO)
Etat_Capteur_Ral_Ouv
Opening slowdown sensor status (NO)
Etat_Capteur_Ral_Ferm
Closing slowdown sensor status (NO)
Etat_Capteur_Fdc_Ferm
Closing end-of-travel sensor status (NO)
Report_Barriere_Ouverte
Open barrier report status (NO)
Report_Barriere_Fermee
Closed barrier report status (NO)
Report_Barriere_Degondee
Unhinged barrier report status (NC)
Report_Boucle_Securite
Safety loop presence report status (NO)
Report_Barriere_Defaut
Barrier fault report status (NO)
Sortie_Feu_Flash
Flashing light output status (NO)
Sortie_Feux_Sur_Lisse
Light output on arm status (NO)
Sortie_Verrouillage
Locking output status (NO)
Sortie_Alarme_Degondage
Unhinging alarm output status (NO)
Sortie_Feu_Vert
Green light output status (NO)
Sortie_Feu_Rouge
Red light output status (NO)
Nbre_Cycles
Number of cycles carried out by the barrier (opening)
Nbre_Degondages
Number of unhingings the barrier has been subjected to
Erreur_Moteur
Motor error code in case of fault (see §3.2. Messages for
safety activation of the barrier)