Use and Care Manual

cleaning if the unit seems to not be operating
optimally or the unit has been running in a highly
dusty environment without the filter (not
recommended). Remove the 4 screws holding the
brackets for the core located under the filter. Be
careful to not drop screws into the coil area. Pull the
core straight up by the metal frame surrounding it on
the top. Clean the core with warm soapy water.
Replace, making sure the rear metal frame is facing
the rear sealing frame inside the unit. Take care to
make sure the seal is good as any air leakage will
cause the unit to under-perform. Attach the brackets
on the top with the screws loosely, and then apply
sideways pressure to ensure a good seal between
the frame and the core. Start up the unit and listen
for air whistling, if there are any leaks, readjust the
brackets.
STORAGE
Freezing temperatures and biological growth must
be considered before storing the dehumidifier. The
dehumidifier should be flushed with a bio fungicide
before storing. When storing the unit, ensure that
water has been removed from the reservoir and
hose. This will prevent damage caused by freezing
temperatures and to prevent biological growth. Use
the pump purge button to remove water and bio
fungicide chemicals from the dehumidifier. When
that is complete, open the valve located in the wheel
well on the right side of the unit. Pushing the insert
in will open it, removing the red ring from sight.
Pressing the steel catch will close the valve,
popping insert partially out, red ring should then
be showing! (See picture) Opening this valve
allows the pump reservoir to empty completely for
storage to avoid damage to the condensate pump in
freezing conditions.
PLEASE NOTE: OPENING THE HOSE INSERT
WILL ALLOW WATER TO DRAIN FROM PUMP
AS SOON AS IT IS OPENED. MAKE SURE YOU
ARE IN AN AREA WHERE THERE WILL BE NO
DAMAGE FROM WATER DRAINING OUT OF THE
UNIT BEFORE DOING THIS!!!!
ENSURE INSERT FOR THE PUMP RESERVOIR IS
CLOSED (red ring should be showing) BEFORE
STARTING THE UNIT!!!!
STACKING
DO NOT STACK THE DEHUMIDIFIERS!
SERVICE
A qualified refrigeration technician must service all
refrigerant leaks.
WARNING: The dehumidifier uses a high
pressure refrigerant system and high voltage
circuitry, which could present a health hazard,
resulting in death, serious bodily injury, and/or
property damage. Only qualified service people
should service this unit.
The serial data plate is located on the rear panel of
the dehumidifier.
For service information contact: 877.800.BAIR
(2247) or email warranty@b-air.com