USB 2.0 Ranger 2304 ® 4-Port USB 2.
Thank you for purchasing the USB 2.0 Ranger® 2304. Please read this guide thoroughly. This document applies to Part Numbers: 00-00347, 00-00348, 00-00349, and 00-00350. FCC Radio Frequency Interference Statement Warning This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
Contents Introduction..............................................................................................................3 Ranger 2304-LAN Product Contents............................................................................................. 3 Features................................................................................................................................................... 3 The LEX Unit.................................................................................
Introduction This guide provides product information for the Ranger 2304 installation instructions, troubleshooting guidelines, and instructions for contacting Icron regarding technical support and warranty information. The instructions in this guide assume a general knowledge of computer installation procedures, familiarity with cabling requirements, and some understanding of USB devices. note NOTE: Notes provide additional information that could be useful.
The LEX Unit The Local Extender (LEX) unit connects to the computer using a standard USB 2.0 cable. Power for this unit is provided by the the host computer. Front View Rear View ITEM TYPE DESCRIPTION Power LED (Blue) LED turns on when power is supplied, off when no power is supplied by the Host computer. 2 Link LED (Green) Indicates a valid ExtremeUSB link is established between the LEX and REX units.
The REX Unit The Remote Extender (REX) unit provides USB Type A ports for standard USB devices. The REX unit allows you to connect up to four USB devices directly. Additional devices may be connected by attaching USB hubs to the REX unit. The REX unit is powered by an external AC adapter and can supply up to 500mA to each USB port. Front View Rear View ITEM TYPE DESCRIPTION 1 USB Device Ports Accepts USB device(s) using Type A connectors.
Installing the Ranger 2304 System Requirements To complete the installation, you will also require the following items that are not included with the product: • USB compatible computer (host computer) with a USB compliant operating system • USB compatible device(s) • Cat 5e Unshielded Twisted Pair (UTP) cable with two RJ45 connectors (if using surface cabling), OR, Cat 5e cabling with two information outlets and two Cat 5e patch cords with RJ45 connectors (if using premise cabling) Computer USB cable Cat
Installing the LEX Unit 1. 2. Place the LEX unit near the computer. Connect the supplied USB cable between the LEX host port and a USB port on the host computer. Connecting the LEX Unit to the REX Unit With Surface Cabling 1. 2. Connect the Cat 5e cable into the Link port of the LEX unit. Connect the Cat 5e cable into the Link port of the REX unit. With Premise Cabling 1. 2. 3. 4. Connect a Cat 5e patch cable (not provided) into the information outlet near the host computer.
Checking the Installation 1. On the LEX and REX units, check that the Power, Status, Link and Host LEDs are on. • If the Host or Link LEDs are permanently off, then the cabling between the LEX and REX units may not be installed properly or is defective. 2. For Windows users (XP, 7, 8), open Device Manager to confirm that the Ranger 2304 has installed correctly. Expand the entry for Universal Serial Bus controllers by clicking the “+” sign.
Connecting a USB Device 1. 2. 3. Install any software required to operate the USB device(s). Refer to the documentation for the USB device(s), as required. Connect the USB device to the device port on the REX unit. Check that the device is detected and installed properly in the operating system. Compatibility The USB 2.0 Ranger 2304 complies with USB 1.1 and USB 2.0 specifications governing the design of USB devices.
Troubleshooting The following table provides troubleshooting tips. The topics are arranged in the order in which they should be executed in most situations. If you are unable to resolve the problem after following these instructions, please contact Technical Support for further assistance. PROBLEM All LEDs on LEX unit are off. CAUSE • The LEX unit is not receiving power from the USB port. SOLUTION 1. Ensure that the host computer is connected to the LEX. 2.
Contacting Technical Support If you are experiencing problems not referenced in the Troublehooting section, you may contact Icron Technical Support at icron.com/support. Warranty Information Limited Hardware Warranty Icron Technologies Corporation warrants that any hardware products accompanying this documentation shall be free from significant defects in material and workmanship for a period of two years from the date of purchase.
Obtaining Warranty Service To obtain warranty service, you must first contact Icron Technologies Corporation within the warranty period for a Return Material Authorization (RMA) number. Icron Technologies Corporation will not accept returns without an authorized RMA number. Be sure you have the serial numbers of the local extender and remote extender before calling. Package the product appropriately for safe shipment and mark the RMA number on the outside of the package.
Technical Glossary Category 5e (Cat 5e) Network Cabling Category 5e cable is commonly also referred to as Cat 5e. This cabling is available in either solid or stranded twisted pair copper wire variants and as UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair). UTP cables are not surrounded by any shielding making them more susceptible to electromagnetic interference (EMI). STP cables include shielding the copper wires and provides better protection against EletroMagnetic Interference (EMI). USB 2.
Specifications RANGE Direct Connect Up to 100m (330 ft) over solid core Cat 5e or better USB DEVICE SUPPORT Maximum USB 2.0 Throughput Up to 480Mbps Maximum USB 1.1 Throughput Up to 12Mbps Traffic Types All USB 2.0 and 1.1 Traffic Types Device Types All USB 2.0 and 1.1 Device Types Number of Devices and/or Hubs 17 LOCAL EXTENDER (LEX) USB Connector 1 x USB 2.0 Type B Receptacle Link Connector 1 x RJ45 Dimensions 100mm x 76mm x 26mm (3.9” x 3.0” x 1.
Icron Technologies Corporation 4664 Lougheed Highway, Suite 221 Burnaby, BC Canada V5C 5T5 Tel: +1 604 638 3920 Fax: +1 604 638 3930 icron.