5. Environmental Specifications
The V-Smart shall be manufactured for indoor use, and if placed outdoors must be
installed within a complete Bioscrypt certified enclosure to protect the reader
against direct contact with the elements, including rain, sun, snow, or excessive
moisture. Failure to place V-Smart readers installed outdoors within such an
enclosure will void the warranty.
5.1. Bioscrypt Enclosure
The Bioscrypt certified enclosure shall be required for outdoor installations and
shall optionally include a heater that shall trigger on when temperatures
reach below 24° C (75° F). For further information on the Bioscrypt certified
enclosure, including power requirements and schematics, please contact
Bioscrypt Technical Support.
5.2. Temperature
The electronics and mechanical parts that make up the V-Smart reader shall
be rated to operate in a temperature range of 0° C to 60° C (32° F to 140° F).
However, the extremes of this temperature range will not be a comfortable
operating range for users of the system. The temperature range for the
environment in which the reader will be installed should be limited to 10° C to
50° C (50° F to 120° F). Additionally, the reader should not be placed in direct
sunlight or in uncontrolled environments (indoors or out).
5.3. Humidity
The V-Smart reader shall be rated to operate within a humidity range of 0% to
95% non-condensing.
5.4. Vibration
The environment in which the V-Smart shall be installed should not subject the
reader to vibration.
6. Electrical Specifications
6.1. Pigtail Connections
The V-Smart reader shall include a 15-pin DB15M connector for external
connections to power and other devices. A 15-conductor color-coded pigtail