example, at 9600 baud, a distance of 150 feet is possible using shielded
cable, but at 57600 baud, a maximum of 20 feet is recommended. By
default, this port will be configured for 57600 baud.
To create your own RJ11-to-DB9 cable the following is required:
Use Category 5 rated cable (shielded is recommended). This cable
should be dedicated to the RS-232 connection between the V-Smart
reader and the PC or host device.
Use a female DB9 connector.
Use a 6p6c RJ11 jack.
Orient the jack so that the 6 gold pins are facing upward and the jack
(or clip) is facing the user. Pin 1 would be on the far left and Pin 6 would
be on the far right.
Connect the RJ11 Pin 1 (RS-232 Tx) to the DB9 Pin 2.
Connect the RJ11 Pin 2 (RS-232 Rx) to the DB9 Pin 3.
Connect the RJ11 Pin 5 (Signal GND) to the DB9 Pin 5.
8. Connections to External Equipment
8.1. Power
The V-Smart reader shall require an isolated power supply (not provided with
reader). This power supply may be optionally purchased from Bioscrypt. Two
conductors shall be required for this connection (Pins 11 & 13). Since the
reader requires significant power levels (see Section 6.2: Power
Requirements), the cable should be of appropriate gauge (18 AWG or better
is recommended).
8.2. Earth Ground
The V-Smart reader shall require a homerun connection to Earth Ground using
Pin 15. This connection shall help to protect the V-Smart (sensor and internal
electronics) from electro-static discharge (ESD) by providing a safe discharge
path to an earth ground. Pin 15 must be connected to a proper earth ground
such as a cold-water copper pipe or building ground. The connection
chosen for Earth Ground should measure less than 4 ohms resistance when
measured against a known local Earth Ground. DO NOT CONNECT PIN 15 TO
POWER GROUND. At a minimum, this connection should be made with a low-
resistance, single-conductor cable (14 – 18 AWG is recommended). Internally,
Pin 15 is connected to the finger mask (conductive plastic surrounding the
fingerprint sensor) and should be used in conjunction with the Ridge-Lock.