Specifications

Page 17
Document# 430-00137-03 © Copyright 2003-2006, Bioscrypt Inc. All rights reserved.
Pin 6 acts as the reference ground for the Wiegand Data 0 and Data 1
interface.
8.4. Access Control System
The V-Smart reader shall support Wiegand protocol output for connection to
an Access Control System (ACS). This system may provide advanced access
control features such as audit trails, user-defined access scheduling, anti-
passback, etc.
The V-Smart by default shall generate a Wiegand output sequence based on
the fingerprint template ID number, unless a Wiegand sequence has been
provided to the V-Smart reader during enrollment and stored on the smart
card. Please refer to Section 8.3: External Wiegand Reader for further details.
An 18 – 22 AWG cable should be used for this connection. At 18 AWG, a
distance of 500 feet is possible. For Wiegand output the V-Smart reader shall
require a homerun connection to the ACS using the following three
conductors:
Wiegand Out Data 0 (Pin 1) connected to the ACS Data 0
Wiegand Out Data 1 (Pin 3) connected to the ACS Data 1
Wiegand GND (Pin 6) connected to the ACS reader power GND (0
VDC)**
The V-Smart reader shall by default have the Wiegand output activated for
Standard 26-bit Wiegand format. The reader shall support other formats. Refer
to Appendix B: Wiegand Protocol for further information.
**Wiegand GND (Pin 6) should be commoned to both Power GND on the
external Wiegand reader and Access Control System reader Power GND. Pin
6 acts as the reference ground for the Wiegand Data 0 and Data 1 interface.
8.5. Line Trigger
The V-Smart reader shall include a Line Trigger, a low-level signal that is
triggered following a successful verification. By default, this line shall be
inactive and must manually be activated through use of the VeriAdmin
management software provided with the reader. When the Line Trigger is
activated, the user must also specify the duration (in seconds) the trigger
should be set high. This source output is an open-drain drive capable of 50