User`s guide

Airborne Industrial Wireless Device
Server SSEW-100D
Quatech Corporation
The SSEW-100D is a serial server that
provides RS-232 to 802.11g conversion
and transport of serial data over an IP
network. The SSEW-100D is available in
a one port version. The two port version
is the DSEW-100D.
Directions included below may also be
found in the Quatech Serial Device
Server User’s Manual. The document is
shipped with the SSEW-100D and is
available on the Quatech website at
http://wwwquatech.com.
Cabling
The SSEW-100D has a DB-9 connector
for the serial port on the bottom edge.
Use the standard serial cable as
described on page 3.
Antenna
The standard antenna supplied with the
unit is not suitable for external mounting.
Additional antenna options are available
from the vendor and third parties.
Network Configuration
The SSEW-100D must be setup to ensure
the proper serial port settings are
configured to communicate with the
Opticom™ Infrared phase selector over
the RS-232 interface and that the proper
network configurations are made to allow
the SSEW-100D to be found on the
network by the central management
software. The unit must be configured
with a static IP address.
Select Static IP address.
Specify the IP address to be used by this
device.
Specify the Address Mask (usually
255.255.255.0).
Specify the Gateway Address.
Specify an SSID for the access point to
connect to.
Specify the Access Mode to
Infrastructure.
Specify any wireless security if needed.
GTT tested with WPA-PSK.
Refer to the SSEW-100D User’s Guide for
instructions on how to access the
configurations via the internal web pages.
Serial Port Configuration
The Serial Port Setup specifies the type of
transport communications means which
will be used to ferry the RS-232 serial
data over the IP network. Central
management software supports TCP
sockets and COM ports.
The SSEW-100D supports five (5)
operating modes: Normal, Tunneling,
Raw TCP, Auto TCP, and Raw UDP.
Selection of Normal allows the unit to be
used with COM redirector software.
Specify Raw TCP mode for use with TCP
sockets.
Installation of the Quatech device as a
multi-port serial device on a PC or server
sets up the COM port redirector software
so that the device appears as a COM
port. Configure the serial port
configuration as described in the
Required Serial Settings on page 3.
Compatibility Test Configuration
Device model: SSEW-100D
Device firmware: 6.39
Comm modes: TCP/IP, redirected serial.
Testing was performed with a mix of
wireless and hard-wired Ethernet
Software: Central Management Software
1.5
Phase selector: Opticom Infrared Model
752 / 754