User manual

Typ Colour Part nr.
LC-Mini 120 white 91051
LC-Mini 120 black 91071
LC-Mini 180 white 91052
LC-Mini 180 black 91072
Accessory:
RC-Suppressor 10880
15.
Article / Part nr. / Accessory
14. Technical data
Power supply
: 230 V~ ±10 %
Detection area
: LC-Mini 120
120°
LC-Mini 180
180°
Range of coverage in m:
max. 10 m when walki
n
g across (tangential
)
Degree of protection/class:
IP 44 / II /
Dimension:
L 80 x B 55 x H 70 mm
Ambiente temperature: -25°C to +50°C
Package:
Housing UV- and
shock-resistant Polycarbonate
Chanel 1 for light control
Contact load:
1000 W, cosφ = 1
Time-settings:
4 s - 10 min.
Brightness value: 2 - 2000 Lux
Declaration of Conformity:
The product complies with the low voltage
recommendation 2006/95/EC/ and the EMV
recommendation 2004/108/EC.
12. Dimensions (mm)
MAN 6936 – 181113 -3
11. Wiring diagrams
N
L
N L L‘
C1
E1
L
N
E1 S1
RC
N L L‘
C1
N
N
L
L
L‘
C1
E1T7
L
L L
C1
C1
L‘
L‘
N
N
N
E1
L
L
L
L‘
N
N
N
E1
T1
T2
30 s -
10min.
4
3
13.
Trouble Shooting-Practical hints
1. Lamp does not light up
Cause - Action
Lamp is defective
- Replace light bulb.
No mains connection
- Check mains fuse.
Switching threshold of the twilight switch is not
correct
- Accordingly adjust sensitivity of twilight
switch via the setting dial.
Detection area not set correctly
Set detection area correctly.
Unit mounted too high
- Mount at recommended height (2.50 m)
PIR detector lens obstructed by dirt or other
objects
- Clean lens or remove objects
2. Delayed lamp activation
Mounted too high
- Mount at height stated in specication
(2.5 m)
Only direct in-line approach of detector is
possible
- Mount detector in such a way that a
sideways approach is also detected.
3. Lamp stays on continuously
Continuous thermal movement within detection
area
- Remove the heat source out of the detection
area.
Check the correct functioning of the detector
in fully covering the lens (lights should go out
after a certain time-delay).
Motion detector is switched parallel to a switch
that enables direct manual switching on
- Mind the correct connection of the switch.
4. Light source remains on for long periods
when no persons are present
Permanent inuence from heat sources within
detection area (trees, shrubs when blown by
the wind, presence of animals like cats and
dogs in the detection area)
- Reduce detection area of the detector in
turning the detector head downward or
cover parts using the enclosed covers.
Direct sunlight radiation into detector lens
- Shelter lens from direct sunlight.
Detector mounted above extractor fan
- Change mounting place of the detector.
5. Limitation of range (not up to the minimum
specication)
Mounting height is not optimal
- Accordingly change mounting height
(2.50 m).Persons only move directly towards
the detector
- Mount detector in such a way that a
sideways approach is also detected.
Steep terrains
- Adjust spherical head accordingly.
6. No reaction to vehicles
Vehicle not warmed up
Vehicle is well insulated (by silencing equip-
ment)
Standard mode with 1-channel motion detector
Standard mode with 1-channel motion detector with
permanent light function
Standard mode with 1-channel motion
detector with NC pushbutton
Parallel connection with 1-channel motion detectors
Standard mode with 1-channel motion detector
(e.g. stairs)
optional:
S1 = switch for permanent light
RC = RC-suppression kit if required
T 1 = NC button
Manual switching addition-
ally possible (press opener
approx. 2 sec.).
38
7
41
10
7
48
22
58
22
L
N