User manual

B&G Hydra & Hercules User Manual
Part 5 - Options
HB-0842
5-15
5.2.5 Hydraulic Drive Pumps
The Reversible Hydraulic Drive Pump has a small high speed pump
driven by a 12 or 24V DC permanent magnet motor. The pump has
pilot check valves to prevent back driving and a pilot operated
reservoir valve to enable the unit to drive balanced or unbalanced
cylinders. The unit has Port and Starboard 1/4" BSP service ports and
a 1/4" BSP reservoir port. Adapters for 1/4" BSP to NTP are
available.
Hydraulic Pump
Type
PMP-T1-12V PMP-T2-12V PMP-T3-24V
Pump Type Reversible DC
motor
Reversible DC
motor
Reversible DC
motor
Supply Voltage 12V DC 12V DC 24V DC
Typical
Operating
Current
5-17.5A 5-22.5A 6-17.5A
Maximum
Pressure
1000 psi 1000 psi 1000 psi
Maximum Flow
Rate
750 cc/min,
46 ins
3
/min
1420 cc/min,
87 in
3
/min
1980 cc/min,
121 in
3
/min
Cylinder
Capacity
100 - 300 cc,
6.1 - 18.3 in
3
275 - 550 cc,
16.8 - 33.6 in
3
525 - 750 cc,
32 - 46 in
3
Weight 3 kg
6.6 lbs
3 kg
6.6 lbs
4 kg
8.8 lbs
Table 5.3 Hydraulic Drive Pump Data
KEY POINTS ON INSTALLATION
A position should be chosen convenient for the steering system
hydraulic delivery lines.
The site should be rigid and flat to prevent excess vibration.
Shielded from the direct effects of the elements.
Minimise the lengths of the hydraulic lines from the pump to the
cylinder and where possible the pump motor supply cables.