5.2.5 Hydraulic Drive Pumps
The Reversible Hydraulic Drive Pump has a small high speed pump
driven by a 12 or 24V DC permanent magnet motor. The pump has
pilot check valves to prevent back driving and a pilot operated
reservoir valve to enable the unit to drive balanced or unbalanced
cylinders. The unit has Port and Starboard 1/4" BSP service ports and
a 1/4" BSP reservoir port. Adapters for 1/4" BSP to NTP are
available.
Hydraulic Pump
Type
PMP-T1-12V PMP-T2-12V PMP-T3-24V
Pump Type Reversible DC
motor
Reversible DC
motor
Reversible DC
motor
Supply Voltage 12V DC 12V DC 24V DC
Typical
Operating
Current
5-17.5A 5-22.5A 6-17.5A
Maximum
Pressure
1000 psi 1000 psi 1000 psi
Maximum Flow
Rate
750 cc/min,
46 ins
3
/min
1420 cc/min,
87 in
3
/min
1980 cc/min,
121 in
3
/min
Cylinder
Capacity
100 - 300 cc,
6.1 - 18.3 in
3
275 - 550 cc,
16.8 - 33.6 in
3
525 - 750 cc,
32 - 46 in
3
Weight 3 kg
6.6 lbs
3 kg
6.6 lbs
4 kg
8.8 lbs
Table 5.3 Hydraulic Drive Pump Data
KEY POINTS ON INSTALLATION
• A position should be chosen convenient for the steering system
hydraulic delivery lines.
• The site should be rigid and flat to prevent excess vibration.
• Shielded from the direct effects of the elements.
• Minimise the lengths of the hydraulic lines from the pump to the
cylinder and where possible the pump motor supply cables.