Installation manual

| 57
Troubleshooting | B&G Triton Display Installation Manual
DRAFT COPY
Troubleshooting
Issue Solution
Unit does not power up • Check that the NMEA2000/
SimNet network has 12V
connected.
• Try connecting to a
different network cable in
case power wires damaged
internally.
Unit does not show data for a
specific source
• In the advanced setup
menu, select sources,
and manually select the
required data source.
• Check the network
connection on the data
source.
Unit does not show any data
from any connected source
or
Unit data sources intermittently
drop out.
• In the advanced setup
menu, select sources
option, then select AUTO
SELECT.
• Check the Device List menu
and see if any devices are
detected.
• Try connecting to a
different network cable in
case data wires damaged
internally.
• In the advanced setup
menu, check the
diagnostics page to see if
any errors are occurring.
• Check network topology
and termination rules are
correctly implemented.
• Disconnect other devices
fromnetwork,one-by-one,
starting with 3rd party
devices.