Specifications
| 21
Operation | Triton Operator Manual
Alarm types
Alarm Value Alarm description Type
Disable all alarms OFF All alarms off .- NO Alarms will be raised! Cont’
Shallow water m Shallow water limit - Meters Cont’
Deep water m Deep water limit - Meters Cont’
High wind kn Max wind speed - Knots Cont’
Off course nm Max off course distance - Nautical miles Cont’
Anchor alarm N/A
Use when at anchor. The alarm will sound
when there is a signifi cant change of
depth caused by a change in tide or
boat drifting into deeper or shallower
water. The anchor depth alarm value is
predefi ned in the software and cannot be
confi gured by the user. The anchor alarm
should be turned off when the boat is not
at anchor.
Cont’
Pilot system alarms only
Wind shift º Maximum wind shift - Degrees Cont’
Depth data missing N/A
Missing data
Single
Wind data missing N/A Single
Navigation data missing N/A Single
Compass data missing N/A Single
Speed data missing N/A Single
Position data missing N/A Single
Rudder feedback failure N/A
Pilot failure
Cont’
Rudder response failure N/A Cont’
Drive overload N/A Single
High temperature N/A Single
Bypass/clutch overload N/A Single
Bypass/clutch disengaged N/A Single
High drive supply N/A Single
Low drive supply N/A Single
No active control unit N/A Single
No autopilot computer N/A Single
ACXX Memory failure N/A Single
RF must be calibrated N/A Single
Key: Alarm type. Single = Single sound alarm, Cont’ = Continuous sound alarm. Both types of
alarm will have a notifi cation appear on the display until the alarm is acknowledged.