Manual

www.bk precision.com
Tel.: 714.921.9095
DC Volts
R
anges 400 mV, 4 V, 40 V, 400 V, 1000V
R
esolution 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
Accuracy ±(1.0 % rdg + 2 dgts)
I
nput Impedance 400 mV: >100 M; 4 V: 10 M; 40 V to1000 V: 9.1 M
O
verload Protection 1000 VDC or 750 VACrms
AC Volts (50 Hz-500 Hz)
Ranges 400 mV, 4 V, 40 V, 400 V, 750V
Resolution 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V
A
ccuracy 50 Hz to 100 Hz ±(2.0 % rdg + 5 dgts)
I
nput Impedance 400 mV: >100 M; 4 V: 10 M; 40 V to 750 V: 9.1 M
Overload Protection 1000 VDC or 750 VACrms
DC Current
R
anges 400 uA, 4000 uA, 40 mA, 400 mA, 10 A
R
esolution 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA
Accuracy 400 uA to 400 mA ranges: ±(2.0 % rdg + 2 dgts)
1
0 A range: ±(3.0 % rdg + 3 dgts)
I
nput Protection 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input 10 A for 60 sec max. followed by a 10 minute cooling period
AC Current (50 Hz-500 Hz)
R
anges 400 uA, 4000 uA, 40 mA, 400 mA, 10 A
R
esolution 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA
Accuracy 400 µA to 400 mA ranges: ±(2.5 % rdg + 5 dgts)
10 A range: ±(3.5 % rdg + 5 dgts)
Input Protection 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses
10A Input 10 A for 60 sec max. followed by a 10 minute cooling period
Resis tance
Ranges 400 , 4 k, 40 k, 400 k, 40 M
Resolution 0.1 , 1.0 , 10 , 100 , 10 k,
Accuracy 400 to 400 k ranges: ±(1.5 % rdg + 4 dgts)
4 M range: ±(2.5 % rdg + 4 dgts)
40 M range: ±(5.0 % rdg + 4 dgts)
Open Circuit Voltage (typical) -0.45 VDC (-1.2 VDC on 400 range)
Overload Protection 500 VDC/ACrms
Diode Test
Test Current 1.0 mA (typical)
Resolution 10 mV
Accuracy ±(3.0 % rdg + 3 dgts)
Audible Indication <0.25 V
Open Circuit Voltage 3.0 VDC (typical)
Overload Protection 500 VDC/ACrms
Continuity
Audible Indication Less than 25
Response Time 500 ms
Overload Protection 500 VDC/ACrms
General
Display 3 3/4 digit, 4000 count LCD
Polarity Automatic, positive implied, negative polarity indication
Overrange OL or -OL is displayed
Low Battery Indication Battery symbol will display when battery voltage drops below
operating levels
Measurement Rate 2 times per second
Auto Power Off Approximately 10 minutes
Operating Environment 0ºC to 50ºC at <70 % relative humidity
Storage Environment -20ºC to 60ºC at 0 to 80 % relative humidity
Accuracies Stated accuracy at 23ºC ±5ºC at <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 200 hours typical
Dimensions 165 mm (H) x 78 mm (W) x 42.5 mm (D)
Weight Approximately 10 oz. (285 g) with battery and hanger
Auto Ranging Tool Kit
®
DMM
Model 2705B
Data Sheet
Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2
The 2705B is a full-featured auto-ranging DMM that combines performance,
value and functionality. The 3400 count LCD can display resistance values up to
40 M. With the auto-power-off feature, you won’t have to worry about
accidental battery consumption. Value-packed features make this meter a must in
every "Tool Kit
®
".
Features
Magnetic hanger
One-handed operation
Auto/manual ranging
Auto power off
Measures up to 10 A (AC & DC)
DC voltage to 1000 V
AC voltage to 750 V
Resistance to 40 M
Continuity test
Diode test
Specifications
2705B
model
Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed)
Three-Year Warranty
Select between Auto or
Manual ranging
Aut o/ Manual Ranging

Summary of content (2 pages)