Manual

24
The transition time range is 5 ns to 100 ms, but the value is limited to a 20:1 ratio between the transition
times. In addition, both values must be within one of the following ranges:
5 ns 100 ns
50 ns – 1 µs
500 ns 10 µs
5 µs 100 µs
50 µs – 1 ms
500 µs 10 ms
5 ms 100 ms
The transition times are also limited by the values of the period, width and delay.